Protect yourself against future threats.
-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA256 =========================================================================== AUSCERT External Security Bulletin Redistribution ESB-2023.0510 Advisory (icsa-23-026-05) Mitsubishi Electric MELFA SD/SQ series and F-series Robot Controllers 27 January 2023 =========================================================================== AusCERT Security Bulletin Summary --------------------------------- Product: Mitsubishi Electric MELFA SD/SQ series and F-series Robot Controllers Publisher: ICS-CERT Operating System: Network Appliance Resolution: Patch/Upgrade CVE Names: CVE-2022-33323 Original Bulletin: https://us-cert.cisa.gov/ics/advisories/icsa-23-026-05 Comment: CVSS (Max): 7.5 CVE-2022-33323 (CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N) CVSS Source: ICS-CERT Calculator: https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N - --------------------------BEGIN INCLUDED TEXT-------------------- ICS Advisory (ICSA-23-026-05) Mitsubishi Electric MELFA SD/SQ series and F-series Robot Controllers Original release date: January 26, 2023 Legal Notice All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/ . 1. EXECUTIVE SUMMARY o CVSS v3 7.5 o ATTENTION: Exploitable remotely/low attack complexity o Vendor: Mitsubishi Electric Corporation o Equipment: MELFA SD/SQ series and F-series Robot Controllers o Vulnerability: Active Debug Code 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to gain unauthorized access to a robot controller. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Mitsubishi Electric reports this vulnerability affects the following Robot Controllers: o MELFA SD/SQ Series: firmware version S7x and prior o MELFA SD/SQ Series: firmware version R7x and prior o MELFA F-Series: firmware version S7x and prior o MELFA F-Series: firmware version R7x and prior Note: The affected firmware version depends on the model name; see Mitsubishi Electric's publication for the specific model names and controller types. 3.2 VULNERABILITY OVERVIEW 3.2.1 ACTIVE DEBUG CODE CWE-489 An authentication bypass vulnerability due to active debug code exists in Mitsubishi Electric MELFA SD/SQ series and F-series controllers for industrial robots. An attacker could gain unauthorized access to a robot controller by performing an unauthorized telnet login. CVE-2022-33323 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is ( AV:N/AC:L/PR:N/UI:N/S:U/ C:N/I:H/A:N ). 3.3 BACKGROUND o CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing o COUNTRIES/AREAS DEPLOYED: Worldwide o COMPANY HEADQUARTERS LOCATION: Japan 3.4 RESEARCHER Mitsubishi Electric reported this vulnerability to CISA. 4. MITIGATIONS Mitsubishi Electric released new firmware versions to address the issue. The fixed firmware version depends on the model name. Users should contact Mitsubishi Electric to obtain the latest firmware version: o MELFA SD/SQ Series: Update to firmware version S7y or later o MELFA SD/SQ Series: Update to firmware version R7y or later o MELFA F-Series: Update to firmware version S7y or later o MELFA F-Series: Update to firmware version R7y or later Mitsubishi Electric recommends users take the following mitigation measures to minimize the risk of an attacker exploiting this vulnerability: o Use a firewall or virtual private network (VPN), etc. to prevent unauthorized access when internet access is required. o Use affected products within a local area network (LAN) and block access from untrusted networks and hosts through firewalls. For specific update instructions and additional details, see the Mitsubishi Electric advisory . CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability these vulnerabilities. Specifically, users should: o Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet . o Locate control system networks and remote devices behind firewalls and isolate them from business networks. o When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage at cisa.gov/ics . Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies . Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies . Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploits specifically target this vulnerability. For any questions related to this report, please contact the CISA at: Email: CISAservicedesk@cisa.dhs.gov - --------------------------END INCLUDED TEXT-------------------- You have received this e-mail bulletin as a result of your organisation's registration with AusCERT. The mailing list you are subscribed to is maintained within your organisation, so if you do not wish to continue receiving these bulletins you should contact your local IT manager. If you do not know who that is, please send an email to auscert@auscert.org.au and we will forward your request to the appropriate person. NOTE: Third Party Rights This security bulletin is provided as a service to AusCERT's members. As AusCERT did not write the document quoted above, AusCERT has had no control over its content. The decision to follow or act on information or advice contained in this security bulletin is the responsibility of each user or organisation, and should be considered in accordance with your organisation's site policies and procedures. AusCERT takes no responsibility for consequences which may arise from following or acting on information or advice contained in this security bulletin. NOTE: This is only the original release of the security bulletin. It may not be updated when updates to the original are made. If downloading at a later date, it is recommended that the bulletin is retrieved directly from the author's website to ensure that the information is still current. Contact information for the authors of the original document is included in the Security Bulletin above. If you have any questions or need further information, please contact them directly. Previous advisories and external security bulletins can be retrieved from: https://www.auscert.org.au/bulletins/ =========================================================================== Australian Computer Emergency Response Team The University of Queensland Brisbane Qld 4072 Internet Email: auscert@auscert.org.au Facsimile: (07) 3365 7031 Telephone: (07) 3365 4417 (International: +61 7 3365 4417) AusCERT personnel answer during Queensland business hours which are GMT+10:00 (AEST). On call after hours for member emergencies only. =========================================================================== -----BEGIN PGP SIGNATURE----- Comment: https://auscert.org.au/gpg-key/ iQIVAwUBY9NYDMkNZI30y1K9AQjPaQ//awwhAC8I5LXYjXUIpioV/egKAcQwiW2p KvHpKTPwiAPmkZAgfrLZweYd509aeFc/9q6qtewIsQFpySSXNLo5racz7IGvkGeE 59nvkDYkmc5I/pwmacN+uHqrWIbFyHIjSKK93bW+BjXiraJjCEAEqdH5wfWZVNBR v5HVG3o1+aYlllBn+ZJrO6zI25MYriHpYLSdxv7+dtmn4ZfsBZVY00Eb5X3weA4a mQ1PTOHhUhbrus7yL2G9lbUZaXXlRKYMqkHohNxoWd1vOi2tiqfVLoZeJZM9Z25y bmzEKZo+PCxgOI4v6WAle3/y/YRdGk8tNVMCAsPRp6KS1OUfcci6GAz5a2XH6FtW jiYoQ5ILzXy+y4d8F2ksptQXZVqn4mZ2w9t/1R/y9bsCBEtSJ9IgJVC7eebeF2qU s7SgFKmunJSu5J8Xkkk11f9k8MsDqHuuT99AyqEtFJlhBCP+se7UmBA7udTKJOG6 z6YcejGieKJFHXWJ9wO9pWtZG/XPETrfelafRcWfS/jX7kRkoVEllGGe0A7YAZnS cgSfszDjERyVK/rJMupTHO8waav8Kv81wjFCL1/Tc2GHF7V4Np32CBJMFc3dXiNz WjROtEGptXN+qnNBvjp07kRQdTJSw/uVYEpg1zG1LWMah16HarKPNHyl8SekUFTM a2l725zX8y0= =PgsR -----END PGP SIGNATURE-----