Protect yourself against future threats.
-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA256 =========================================================================== AUSCERT External Security Bulletin Redistribution ESB-2021.4300 Advisory (icsa-21-350-10) Siemens JT2Go and Teamcenter Visualization 17 December 2021 =========================================================================== AusCERT Security Bulletin Summary --------------------------------- Product: Siemens JT2Go and Teamcenter Visualization Publisher: ICS-CERT Operating System: Network Appliance Impact/Access: Execute Arbitrary Code/Commands -- Existing Account Denial of Service -- Existing Account Access Confidential Data -- Existing Account Resolution: Patch/Upgrade CVE Names: CVE-2021-44017 CVE-2021-44015 CVE-2021-44014 CVE-2021-44013 CVE-2021-44012 CVE-2021-44011 CVE-2021-44010 CVE-2021-44009 CVE-2021-44008 CVE-2021-44007 CVE-2021-44006 CVE-2021-44005 CVE-2021-44004 CVE-2021-44003 CVE-2021-44002 CVE-2021-44001 Original Bulletin: https://us-cert.cisa.gov/ics/advisories/icsa-21-350-10 - --------------------------BEGIN INCLUDED TEXT-------------------- ICS Advisory (ICSA-21-350-10) Siemens JT2Go and Teamcenter Visualization Original release date: December 16, 2021 Legal Notice All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/ . 1. EXECUTIVE SUMMARY o CVSS v3 7.8 o ATTENTION: Low attack complexity o Vendor: Siemens o Equipment: JT2Go and Teamcenter Visualization o Vulnerabilities: Out-of-Bounds Write, Use of Uninitialized Variable, Out-of-Bounds Read, Off-by-One Error, Use-after-Free 2. RISK EVALUATION Successful exploitation of these vulnerabilities could lead the application to crash or potentially lead to arbitrary code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of JT2Go and Teamcenter Visualization software tools are affected: o JT2Go: All versions prior to v13.2.0.5 o Teamcenter Visualization: All versions prior to v13.2.0.5 3.2 VULNERABILITY OVERVIEW 3.2.1 OUT-OF-BOUNDS WRITE CWE-787 One of the DLL files associated with this product contains an out-of-bounds write past the end of an allocated structure while parsing specially crafted PDF files, which could allow an attacker to execute remote code. CVE-2021-44001 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is ( AV:L/AC:L/PR:N/UI:R/S:U/ C:H/I:H/A:H ). 3.2.2 OUT-OF-BOUNDS WRITE CWE-787 One of the DLL files associated with this product contains an out-of-bounds write past the end of an allocated structure while parsing specially crafted JT files, which could allow an attacker to execute remote code. CVE-2021-44002 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is ( AV:L/AC:L/PR:N/UI:R/S:U/ C:H/I:H/A:H ). 3.2.3 USE OF UNINITIALIZED VARIABLE CWE-457 One of the DLL files associated with this product is vulnerable to use of uninitialized memory while parsing user supplied TIFF files, which could allow an attacker to cause a denial-of-service condition. CVE-2021-44003 has been assigned to this vulnerability. A CVSS v3 base score of 4.4 has been calculated; the CVSS vector string is ( AV:L/AC:L/PR:N/UI:R/S:U/ C:L/I:L/A:N ). 3.2.4 OUT-OF-BOUNDS READ CWE-125 One of the DLL files associated with this product contains an out-of-bounds read past the end of an allocated buffer when parsing TIFF files, which could be leveraged to leak information. CVE-2021-44004 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is ( AV:L/AC:L/PR:N/UI:R/S:U/ C:L/I:N/A:N ). 3.2.5 OUT-OF-BOUNDS WRITE CWE-787 One of the DLL files associated with this product contains an out-of-bounds write past the end of an allocated structure while parsing specially crafted TIFF files, which could allow an attacker to execute remote code. CVE-2021-44005 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is ( AV:L/AC:L/PR:N/UI:R/S:U/ C:H/I:H/A:H ). 3.2.6 OUT-OF-BOUNDS WRITE CWE-787 One of the DLL files associated with this product contains an out-of-bounds write past the end of an allocated structure while parsing specially crafted TIFF files, which could allow an attacker to execute remote code. CVE-2021-44006 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is ( AV:L/AC:L/PR:N/UI:R/S:U/ C:H/I:H/A:H ). 3.2.7 OFF-BY-ONE ERROR CWE-193 One of the DLL files associated with this product contains an off-by-one error in the heap while parsing specially crafted TIFF files, which could allow an attacker to cause a denial-of-service condition. CVE-2021-44007 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is ( AV:L/AC:L/PR:N/UI:R/S:U/ C:N/I:N/A:L ). 3.2.8 OUT-OF-BOUNDS READ CWE-125 One of the DLL files associated with this product contains an out-of-bounds read past the end of an allocated buffer when parsing TIFF files, which could be leveraged to leak information. CVE-2021-44008 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is ( AV:L/AC:L/PR:N/UI:R/S:U/ C:L/I:N/A:N ). 3.2.9 OUT-OF-BOUNDS READ CWE-125 One of the DLL files associated with this product contains an out-of-bounds read past the end of an allocated buffer when parsing TIFF files, which could be leveraged to leak information. CVE-2021-44009 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is ( AV:L/AC:L/PR:N/UI:R/S:U/ C:L/I:N/A:N ). 3.2.10 OUT-OF-BOUNDS READ CWE-125 One of the DLL files associated with this product contains an out-of-bounds read past the end of an allocated buffer when parsing TIFF files, which could be leveraged to leak information. CVE-2021-44010 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is ( AV:L/AC:L/PR:N/UI:R/S:U/ C:L/I:N/A:N ). 3.2.11 OUT-OF-BOUNDS READ CWE-125 One of the DLL files associated with this product contains an out-of-bounds read past the end of an allocated buffer when parsing specially crafted JT files, which could be leveraged to leak information. CVE-2021-44011 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is ( AV:L/AC:L/PR:N/UI:R/S:U/ C:L/I:N/A:N ). 3.2.12 OUT-OF-BOUNDS READ CWE-125 One of the DLL files associated with this product contains an out-of-bounds read past the end of an allocated buffer when parsing specially crafted JT files, which could be leveraged to leak information. CVE-2021-44012 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is ( AV:L/AC:L/PR:N/UI:R/S:U/ C:L/I:N/A:N ). 3.2.13 OUT-OF-BOUNDS WRITE CWE-787 One of the DLL files associated with this product contains an out-of-bounds write past the end of an allocated structure while parsing specially crafted JT files, which could allow an attacker to execute remote code. CVE-2021-44013 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is ( AV:L/AC:L/PR:N/UI:R/S:U/ C:H/I:H/A:H ). 3.2.14 USE-AFTER-FREE CWE-416 One of the DLL files associated with this product contains a use-after-free vulnerability that could be triggered while parsing specially crafted JT files, which could allow an attacker to execute remote code. CVE-2021-44014 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is ( AV:L/AC:L/PR:N/UI:R/S:U/ C:H/I:H/A:H ). 3.2.15 OUT-OF-BOUNDS READ CWE-125 One of the DLL files associated with this product contains an out-of-bounds read past the end of an allocated buffer when parsing specially crafted CGM files, which could be leveraged to leak information. CVE-2021-44015 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is ( AV:L/AC:L/PR:N/UI:R/S:U/ C:L/I:N/A:N ). 3.2.16 OUT-OF-BOUNDS READ CWE-125 One of the DLL files associated with this product contains an out-of-bounds read past the end of an allocated buffer when parsing specially crafted TIFF files, which could be leveraged to leak information. CVE-2021-44017 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is ( AV:L/AC:L/PR:N/UI:R/S:U/ C:L/I:N/A:N ). 3.3 BACKGROUND o CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing o COUNTRIES/AREAS DEPLOYED: Worldwide o COMPANY HEADQUARTERS LOCATION: Germany 3.4 RESEARCHER Mat Powell of Trend Micro's Zero Day Initiative and Jin Huang from ADLab reported these vulnerabilities. 4. MITIGATIONS Siemens recommends updating to the latest versions, specifically: o JT2Go: Update to v13.2.0.5 or later version . o Teamcenter Visualization: Update to v13.2.0.5 or later version Siemens has identified the following specific workarounds and mitigations users can apply to reduce the risk: o Avoid opening untrusted files from unknown sources in JT2Go and Teamcenter Visualization As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for industrial security , and follow the recommendations in the product manuals. Additional information on industrial security by Siemens can be found at: https://www.siemens.com/ industrialsecurity Please see Siemens security advisory SSA-595101 for more information. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on us-cert.cisa.gov . Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies . Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies . Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents. No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely. For any questions related to this report, please contact the CISA at: Email: CISAservicedesk@cisa.dhs.gov Toll Free: 1-888-282-0870 CISA continuously strives to improve its products and services. You can help by choosing one of the links below to provide feedback about this product. - --------------------------END INCLUDED TEXT-------------------- You have received this e-mail bulletin as a result of your organisation's registration with AusCERT. The mailing list you are subscribed to is maintained within your organisation, so if you do not wish to continue receiving these bulletins you should contact your local IT manager. If you do not know who that is, please send an email to auscert@auscert.org.au and we will forward your request to the appropriate person. NOTE: Third Party Rights This security bulletin is provided as a service to AusCERT's members. As AusCERT did not write the document quoted above, AusCERT has had no control over its content. The decision to follow or act on information or advice contained in this security bulletin is the responsibility of each user or organisation, and should be considered in accordance with your organisation's site policies and procedures. AusCERT takes no responsibility for consequences which may arise from following or acting on information or advice contained in this security bulletin. NOTE: This is only the original release of the security bulletin. It may not be updated when updates to the original are made. If downloading at a later date, it is recommended that the bulletin is retrieved directly from the author's website to ensure that the information is still current. Contact information for the authors of the original document is included in the Security Bulletin above. If you have any questions or need further information, please contact them directly. Previous advisories and external security bulletins can be retrieved from: https://www.auscert.org.au/bulletins/ =========================================================================== Australian Computer Emergency Response Team The University of Queensland Brisbane Qld 4072 Internet Email: auscert@auscert.org.au Facsimile: (07) 3365 7031 Telephone: (07) 3365 4417 (International: +61 7 3365 4417) AusCERT personnel answer during Queensland business hours which are GMT+10:00 (AEST). On call after hours for member emergencies only. =========================================================================== -----BEGIN PGP SIGNATURE----- Comment: http://www.auscert.org.au/render.html?it=1967 iQIVAwUBYbvntuNLKJtyKPYoAQipkxAAmdnHLqdwk5M3vfhxuGA6LbISkAi0XgVi dNokDrTMQQvd2w3DiI5UMMdG2l0t+1Ikaqw8lFkAnTAao/j5k7260xJE0zLaszvS IatPftRY4n4UGKXvZemEwzzqZ8RayebrDVwye/VXXp/SIvdfv6+St+5oMvd2tI0q tLnfU9pKhshGdYISH1mEzSLHFQ6HqDaxbyU1UFzyD9Z7xuPqlBC1Hz3cdCDUQCUH msLAk1c76vSTStdDYJ78UgNWUalwoKiP0Ndadl2A80HpLWdxi05H1vY2Vg6Nwl69 gQlI3MYyrydHyHpO2eAmt/Z0oW3hfiP1CnX/iKjX2Y3EqKOykSVQcU4DYcuaIUBp xTqAZRVI3QVHECmQaOrfggwjmn9x4uIIzHpbKfafXJMlFr4f7EmboKMFDpxwBVUo rn1Bafkj+2krMpTxLquW1nCfHiot/5gPPWCoEHYi/TLZe/WrHoscLynOlmuwFq4F C0f5oSUNPcZxAY46j7A5NXXSnWnnNnGaMiE7f7UnU4L2hpY+X8qeBhlAPQz7OQyU C06hx0vLLLdfc9fIyQWTPESExSXGSXvjpPwM+zesZ/mrd1dcVzWIXDZUBk6Hjgj0 yP9d+wCnI7lJNvQ2YZWo/JDfvHhhshKXfwZQsUJ523Yz9PjASCtH44CiMQ2Jbhu5 f9iWNUKL78k= =U8p0 -----END PGP SIGNATURE-----