Protect yourself against future threats.
-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA256 =========================================================================== AUSCERT External Security Bulletin Redistribution ESB-2021.3525 Advisory (icsa-21-294-03) ICONICS GENESIS64 and Mitsubishi Electric MC Works64 OPC UA 22 October 2021 =========================================================================== AusCERT Security Bulletin Summary --------------------------------- Product: ICONICS GENESIS64 Mitsubishi Electric MC Works64 Publisher: ICS-CERT Operating System: Network Appliance Impact/Access: Denial of Service -- Remote/Unauthenticated Resolution: Patch/Upgrade CVE Names: CVE-2021-27432 Reference: ESB-2021.1652 Original Bulletin: https://us-cert.cisa.gov/ics/advisories/icsa-21-294-03 - --------------------------BEGIN INCLUDED TEXT-------------------- ICS Advisory (ICSA-21-294-03) ICONICS GENESIS64 and Mitsubishi Electric MC Works64 OPC UA Original release date: October 21, 2021 Legal Notice All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/ . 1. EXECUTIVE SUMMARY o CVSS v3 7.5 o ATTENTION: Exploitable remotely/low attack complexity o Vendors: ICONICS, Mitsubishi Electric o Equipment: ICONICS GENESIS64, Mitsubishi Electric MC Works64 o Vulnerability: Uncontrolled Recursion 2. RISK EVALUATION Successful exploitation of this vulnerability could trigger a stack overflow. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following ICONICS and Mitsubishi Electric modules are affected in some third-party OPC Foundation products: o GENESIS64: Versions 10.97 and prior o Hyper Historian: Versions 10.97 and prior o AnalytiX: Versions 10.97 and prior o MobileHMI: Versions 10.97 and prior o MC Works64: Versions 4.04E and prior 3.2 VULNERABILITY OVERVIEW 3.2.1 UNCONTROLLED RECURSION CWE-674 The affected products are vulnerable to an uncontrollable recursion, which may trigger a stack-based buffer overflow. CVE-2021-27432 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is ( AV:N/AC:L/PR:N/UI:N/S:U/ C:N/I:N/A:H ). 3.3 BACKGROUND o CRITICAL INFRASTRUCTURE SECTORS: Multiple Sectors o COUNTRIES/AREAS DEPLOYED: Worldwide o COMPANY HEADQUARTERS LOCATION: ICONICS is headquartered in the United States. Mitsubishi Electric is headquartered in Japan. 3.4 RESEARCHER Eran Jacob with the Otorio Research Team reported this vulnerability to CISA. 4. MITIGATIONS ICONICS and Mitsubishi Electric are releasing Critical Fix Rollup packages or patches that will include the solution to this vulnerability. GENESIS64 Versions 10.97.1 and later will not be vulnerable to this exploit. ICONICS and Mitsubishi Electric recommend users take the following mitigations: o Place control system networks and devices behind firewalls to isolate them from the business network. o Minimize network exposure for all control system devices. Control system devices should not directly face the Internet. o Do not click web links or open unsolicited attachments in e-mail messages. o Leverage OPC UA security and certificates to ensure ICONICS products only connect to trusted OPC UA servers and clients. o Install the applicable Critical Fixes Rollup, if available. ICONICS provides information and useful links related to its security updates at its company website . Mitsubishi Electric provides information and useful links related to its security updates its company website . CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should: o Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet . o Locate control system networks and remote devices behind firewalls, and isolate them from the business network. o When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on us-cert.cisa.gov . Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies . Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies . Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents. No known public exploits specifically target this vulnerability. For any questions related to this report, please contact the CISA at: Email: CISAservicedesk@cisa.dhs.gov Toll Free: 1-888-282-0870 CISA continuously strives to improve its products and services. You can help by choosing one of the links below to provide feedback about this product. - --------------------------END INCLUDED TEXT-------------------- You have received this e-mail bulletin as a result of your organisation's registration with AusCERT. The mailing list you are subscribed to is maintained within your organisation, so if you do not wish to continue receiving these bulletins you should contact your local IT manager. If you do not know who that is, please send an email to auscert@auscert.org.au and we will forward your request to the appropriate person. NOTE: Third Party Rights This security bulletin is provided as a service to AusCERT's members. As AusCERT did not write the document quoted above, AusCERT has had no control over its content. The decision to follow or act on information or advice contained in this security bulletin is the responsibility of each user or organisation, and should be considered in accordance with your organisation's site policies and procedures. AusCERT takes no responsibility for consequences which may arise from following or acting on information or advice contained in this security bulletin. NOTE: This is only the original release of the security bulletin. It may not be updated when updates to the original are made. If downloading at a later date, it is recommended that the bulletin is retrieved directly from the author's website to ensure that the information is still current. Contact information for the authors of the original document is included in the Security Bulletin above. If you have any questions or need further information, please contact them directly. Previous advisories and external security bulletins can be retrieved from: https://www.auscert.org.au/bulletins/ =========================================================================== Australian Computer Emergency Response Team The University of Queensland Brisbane Qld 4072 Internet Email: auscert@auscert.org.au Facsimile: (07) 3365 7031 Telephone: (07) 3365 4417 (International: +61 7 3365 4417) AusCERT personnel answer during Queensland business hours which are GMT+10:00 (AEST). On call after hours for member emergencies only. =========================================================================== -----BEGIN PGP SIGNATURE----- Comment: http://www.auscert.org.au/render.html?it=1967 iQIVAwUBYXIYRONLKJtyKPYoAQgAzQ//dGSDKWWFzHLq8J9UYmd4iEjecf9k1K0l 3thDdf2vufnQ+yDwU96nELJkMSJndI7HgEr9VtBnVpjiwD2nRXR1cmqOtLWkRmX1 CzaLM6A272WrbsLXH8cyDEbOLocbq4y0ps806UiMart+QM1JWf4F8C8ZDqNNaMpE OdyQ/v/HbPx2F0xdUJGyeGH1EcM6RhNocryGfVepjl1rDpuG4wLwQ+dmRlgJail+ P58rvoMn76wQIH5ov8J+ioDF6BOI/LPySigJP1b73bgm4aUo4L0fbDwk667hYhtU ML21vxqZ+BIO6U2Rm3lq3bMP3pX/wYmKbH4NeSBUSYPrIaOuxq3yPC59YIqbGFMl gwhKZglLN3cvBcU/J/LKjq44KmHcU+YS3CapSIuNZWYgciCM2doVAjFXMBRDTZ7m 4PFWKZd/ydLmXC+ykwMv5GAokHZTKTlO2qTFYUd0EzWmbwkK/Rdm9eYyAY5eL49r YMjpK2D6gsKzyuOSWArRctpTVTdelYQOcM8vGeBHrQmyrtGvOFwrIo3RTTh6iwVs sXXdiAbz999pvtTE4738hGUnX8ire7pdlIr8R94tbajY3M8mzGys0C942wHVh+4n W1DBe9VUvIAD/sxB51MyjJanRS2V90uhZX6GxQhFEz1rKP8wZmmN0MS9ezU1Upmc nadl4DFt7+8= =r+Am -----END PGP SIGNATURE-----