Protect yourself against future threats.
-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA256 =========================================================================== AUSCERT External Security Bulletin Redistribution ESB-2021.1900 Advisory (icsa-21-152-01) Siemens SIMATIC S7-1200 and S7-1500 CPU Families 2 June 2021 =========================================================================== AusCERT Security Bulletin Summary --------------------------------- Product: Siemens SIMATIC S7-1200 and S7-1500 CPU Families Publisher: ICS-CERT Operating System: Network Appliance Impact/Access: Execute Arbitrary Code/Commands -- Remote/Unauthenticated Access Confidential Data -- Remote/Unauthenticated Resolution: Patch/Upgrade CVE Names: CVE-2020-15782 Original Bulletin: https://us-cert.cisa.gov/ics/advisories/icsa-21-152-01 - --------------------------BEGIN INCLUDED TEXT-------------------- ICS Advisory (ICSA-21-152-01) Siemens SIMATIC S7-1200 and S7-1500 CPU Families Original release date: June 01, 2021 Legal Notice All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/ . 1. EXECUTIVE SUMMARY o CVSS v3 8.1 o ATTENTION: Exploitable remotely o Vendor: Siemens o Equipment: SIMATIC S7-1200 and S7-1500 CPU Families o Vulnerability: Improper Restriction of Operations within the Bounds of a Memory Buffer\ 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to write arbitrary data and code to protected memory areas or read sensitive data to launch further attacks. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports this vulnerability affects the following SIMATIC S7-1200 and S7-1500 CPU products: o SIMATIC Drive Controller family: All versions prior to v2.9.2 o SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants): All versions o SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants): All versions o SIMATIC S7-1200 CPU family (incl. SIPLUS variants): All versions prior to v4.5.0 o SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants): All versions prior to v2.9.2 o SIMATIC S7-1500 Software Controller: All versions o SIMATIC S7-PLCSIM Advanced: All versions prior to v4.0 3.2 VULNERABILITY OVERVIEW 3.2.1 IMPROPER RESTRICTION OF OPERATIONS WITHIN THE BOUNDS OF A MEMORY BUFFER CWE-119 Affected devices are vulnerable to a memory protection bypass through a specific operation. A remote, unauthenticated attacker with network access to Port 102/TCP could write arbitrary data and code to protected memory areas or read sensitive data to launch further attacks. CVE-2020-15782 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been calculated; the CVSS vector string is ( AV:N/AC:H/PR:N/UI:N/S:U/ C:H/I:H/A:H ). 3.3 BACKGROUND o CRITICAL INFRASTRUCTURE SECTORS: Chemical, Critical Manufacturing, Energy, Food and Agriculture, Water and Wastewater Systems o COUNTRIES/AREAS DEPLOYED: Worldwide o COMPANY HEADQUARTERS LOCATION: Germany 3.4 RESEARCHER Tal Keren from Claroty reported this vulnerability to Siemens. 4. MITIGATIONS Siemens has released updates for several affected products and recommends updating to the latest versions. Siemens is preparing further updates and recommends specific countermeasures for products where updates are not, or not yet available. o SIMATIC Drive Controller family: Update to v2.9.2 or later version o SIMATIC S7-1200 CPU family (incl. SIPLUS variants): Update to v4.5.0 or later version o SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants): Update to v2.9.2 or later version o SIMATIC S7-PLCSIM Advanced: Update to v4.0 or later version Siemens has identified the following specific workarounds and mitigations users can apply to reduce the risk: o Apply password protection for S7 communication. o Disallow client connections via the ENDIS_PW instruction of the S7-1200 or S7-1500 CPU (This blocks remote client connections, even when the client can provide the correct password). o Use the display to configure additional access protection of the S7-1500 CPU (This blocks remote client connections, even when the client can provide the correct password). o Apply "defense in depth" as outlined on pages 12ff of the operational guidelines for industrial security, especially: Plant security: Ensure physical prevention of access to critical components. Network security: Ensure PLC systems are not connected to untrusted networks. System integrity: Configure, maintain, and protect devices by applying applicable compensating controls and using built-in security capabilities. o Update the entire solution to TIA Portal v17 and use TLS communication using individual certificates between PLC, HMIs, and PG/PC For more information about this vulnerability and the associated mitigations, please see SSA-434534 CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should: o Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet . o Locate control system networks and remote devices behind firewalls, and isolate them from the business network. o When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on us-cert.cisa.gov . Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies . Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies . Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents. No known public exploits specifically target this vulnerability. This vulnerability has a high attack complexity. For any questions related to this report, please contact the CISA at: Email: CISAservicedesk@cisa.dhs.gov Toll Free: 1-888-282-0870 CISA continuously strives to improve its products and services. You can help by choosing one of the links below to provide feedback about this product. - --------------------------END INCLUDED TEXT-------------------- You have received this e-mail bulletin as a result of your organisation's registration with AusCERT. The mailing list you are subscribed to is maintained within your organisation, so if you do not wish to continue receiving these bulletins you should contact your local IT manager. If you do not know who that is, please send an email to auscert@auscert.org.au and we will forward your request to the appropriate person. NOTE: Third Party Rights This security bulletin is provided as a service to AusCERT's members. As AusCERT did not write the document quoted above, AusCERT has had no control over its content. The decision to follow or act on information or advice contained in this security bulletin is the responsibility of each user or organisation, and should be considered in accordance with your organisation's site policies and procedures. AusCERT takes no responsibility for consequences which may arise from following or acting on information or advice contained in this security bulletin. NOTE: This is only the original release of the security bulletin. It may not be updated when updates to the original are made. If downloading at a later date, it is recommended that the bulletin is retrieved directly from the author's website to ensure that the information is still current. Contact information for the authors of the original document is included in the Security Bulletin above. If you have any questions or need further information, please contact them directly. Previous advisories and external security bulletins can be retrieved from: https://www.auscert.org.au/bulletins/ =========================================================================== Australian Computer Emergency Response Team The University of Queensland Brisbane Qld 4072 Internet Email: auscert@auscert.org.au Facsimile: (07) 3365 7031 Telephone: (07) 3365 4417 (International: +61 7 3365 4417) AusCERT personnel answer during Queensland business hours which are GMT+10:00 (AEST). On call after hours for member emergencies only. =========================================================================== -----BEGIN PGP SIGNATURE----- Comment: http://www.auscert.org.au/render.html?it=1967 iQIVAwUBYLcPteNLKJtyKPYoAQge7g/9EgHSA2oDiPdlqK5hhEb6o3ynJ9pLqfDv rRT90BIKQvEZG07PMggLRxu2lEXyGZinNwMMcEhen84oFEM/ws1BKr2LRBmWvWdk GMObVq6uo2otxPCWV52w1T5iOOwupv1IbtkqjUVDiy15ByLTstaaCVQlvMUUIi96 uTCh0iLWIhMNDidpDYa8t27IVd1kW742Jy0WOzji3S/uCDJNM6jfy0Siji8Pasti 5DZJsXAzRxZSC7hn5B8aSahbUpPsy/z3A48WjNWgwmWZMFQAcsSiSlJjINkXmEd+ x6r2BcBzdGxZgcISfjuJ8/p1KbbMaTHA/VdVwU0xfUygJ1MWiFpElU/KFtR1WF54 8hSxMK8woj0YYdQjwGrCIQWOP5jyi7nOx5y1bFBphOI5FGwcX7ESnxDVrAYpAZ/p K2QhhgZOkubfVujW/zfWK3gsNB8noFPR7h+wKBMwPMfiiNlj41cMEfHdM0pus/gD u6RHMZJQWecyZcOm3hURUCT18aDXKngBm3GlZemyz/wjx+caaSDdvqGSXONc46qY j4FRAsVGCs17PpvyIFfPwP3HUfbj6RMgjpI2NQJ0o4UYbN9A2Htz/AFEZJRLjhq1 KEC16+j0Py62nDHGv96qwyH3PWIf/EQW6ayEnMEZ4ectWq30OiO+h5XoubgfYePz 7+asJlbs97U= =679o -----END PGP SIGNATURE-----