Protect yourself against future threats.
-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA256 =========================================================================== AUSCERT External Security Bulletin Redistribution ESB-2021.1839 Advisory (icsa-21-147-03) MesaLabs AmegaView 28 May 2021 =========================================================================== AusCERT Security Bulletin Summary --------------------------------- Product: AmegaView Publisher: ICS-CERT Operating System: Network Appliance Impact/Access: Increased Privileges -- Existing Account Execute Arbitrary Code/Commands -- Remote/Unauthenticated Unauthorised Access -- Remote/Unauthenticated Reduced Security -- Remote/Unauthenticated Resolution: Patch/Upgrade CVE Names: CVE-2021-27453 CVE-2021-27451 CVE-2021-27449 CVE-2021-27447 CVE-2021-27445 Original Bulletin: https://us-cert.cisa.gov/ics/advisories/icsa-21-147-03 - --------------------------BEGIN INCLUDED TEXT-------------------- ICS Advisory (ICSA-21-147-03) MesaLabs AmegaView Original release date: May 27, 2021 Legal Notice All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/ . 1. EXECUTIVE SUMMARY o CVSS v3 10.0 o ATTENTION: Exploitable remotely/low attack complexity o Vendor: Mesa Labs o Equipment: AmegaView o Vulnerabilities: Command Injection, Improper Authentication, Authentication Bypass Using an Alternate Path or Channel, Improper Privilege Management 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow remote code execution or allow access to the device. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of AmegaView, a continuous monitoring hardware and software platform, are affected: o AmegaView Versions 3.0 and prior 3.2 VULNERABILITY OVERVIEW 3.2.1 IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN A COMMAND ('COMMAND INJECTION') CWE-77 The affected product is vulnerable to a command injection, which may allow an attacker to remotely execute arbitrary code. CVE-2021-27447 has been assigned to this vulnerability. A CVSS v3 base score of 10.0 has been calculated; the CVSS vector string is ( AV:N/AC:L/PR:N/UI:N/S:C/ C:H/I:H/A:H ). 3.2.2 IMPROPER AUTHENTICATION CWE-287 The affected product's passcode is generated by an easily reversible algorithm, which may allow an attacker to gain access to the device. CVE-2021-27451 has been assigned to this vulnerability. A CVSS v3 base score of 7.3 has been calculated; the CVSS vector string is ( AV:N/AC:L/PR:N/UI:N/S:U/ C:L/I:L/A:L ). 3.2.3 AUTHENTICATION BYPASS USING AN ALTERNATE PATH OR CHANNEL CWE-288 The affected product uses default cookies that could be set to bypass authentication to the web application, which may allow an attacker to gain access. CVE-2021-27453 has been assigned to this vulnerability. A CVSS v3 base score of 7.3 has been calculated; the CVSS vector string is ( AV:N/AC:L/PR:N/UI:N/S:U/ C:L/I:L/A:L ). 3.2.4 IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN A COMMAND ('COMMAND INJECTION') CWE-77 The affected product has a command injection vulnerability that can be exploited to execute commands in the web server. CVE-2021-27449 has been assigned to this vulnerability. A CVSS v3 base score of 9.9 has been calculated; the CVSS vector string is ( AV:N/AC:L/PR:L/UI:N/S:C/ C:H/I:H/A:H ). 3.2.5 IMPROPER PRIVILEGE MANAGEMENT CWE-269 The affected product has insecure file permissions that could be exploited to escalate privileges on the device. CVE-2021-27445 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is ( AV:L/AC:L/PR:L/UI:N/S:U/ C:H/I:H/A:H ). 3.3 BACKGROUND o CRITICAL INFRASTRUCTURE SECTORS: Healthcare and Public Health, Food and Agriculture o COUNTRIES/AREAS DEPLOYED: United States o COMPANY HEADQUARTERS LOCATION: United States 3.4 RESEARCHER Stephen Yackey of Securifera reported these vulnerabilities to CISA. 4. MITIGATIONS MesaLabs has scheduled AmegaView for end-of-life at the end of 2021. Due to this discontinued service, MesaLabs does not plan to release an update to address these vulnerabilities. MesaLabs recommends users upgrade to the newer ViewPoint software that is compatible with AmegaView hardware. CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should: o Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet . o Locate control system networks and remote devices behind firewalls, and isolate them from the business network. o When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on us-cert.cisa.gov . Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies . Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies . Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents. No known public exploits specifically target these vulnerabilities. For any questions related to this report, please contact the CISA at: Email: CISAservicedesk@cisa.dhs.gov Toll Free: 1-888-282-0870 CISA continuously strives to improve its products and services. You can help by choosing one of the links below to provide feedback about this product. - --------------------------END INCLUDED TEXT-------------------- You have received this e-mail bulletin as a result of your organisation's registration with AusCERT. The mailing list you are subscribed to is maintained within your organisation, so if you do not wish to continue receiving these bulletins you should contact your local IT manager. If you do not know who that is, please send an email to auscert@auscert.org.au and we will forward your request to the appropriate person. NOTE: Third Party Rights This security bulletin is provided as a service to AusCERT's members. As AusCERT did not write the document quoted above, AusCERT has had no control over its content. The decision to follow or act on information or advice contained in this security bulletin is the responsibility of each user or organisation, and should be considered in accordance with your organisation's site policies and procedures. AusCERT takes no responsibility for consequences which may arise from following or acting on information or advice contained in this security bulletin. NOTE: This is only the original release of the security bulletin. It may not be updated when updates to the original are made. If downloading at a later date, it is recommended that the bulletin is retrieved directly from the author's website to ensure that the information is still current. Contact information for the authors of the original document is included in the Security Bulletin above. If you have any questions or need further information, please contact them directly. Previous advisories and external security bulletins can be retrieved from: https://www.auscert.org.au/bulletins/ =========================================================================== Australian Computer Emergency Response Team The University of Queensland Brisbane Qld 4072 Internet Email: auscert@auscert.org.au Facsimile: (07) 3365 7031 Telephone: (07) 3365 4417 (International: +61 7 3365 4417) AusCERT personnel answer during Queensland business hours which are GMT+10:00 (AEST). On call after hours for member emergencies only. =========================================================================== -----BEGIN PGP SIGNATURE----- Comment: http://www.auscert.org.au/render.html?it=1967 iQIVAwUBYLA9eeNLKJtyKPYoAQh1Sg/6A3ndCXaTJBbrwrPdTlU70X/NYJDGqdhD WpdxfwVFItS2JTBNL9YksupFn5TUduP54858suDeUdekeFj0hCqDyk+wd/xSZBwf vxWkEp7HhCWH5aWsn7Tk+BVlgkFP6U+Ib9+yxq+6cs0T1YvS+pzvbln+y2yWU/Oa YGNKY7NksCh4iF2Jc/nFGQ5hQ77vUDPrU9mHMRW2ADASCUvmUhByfVnbKiAtzAa4 G/oKjlpLuJZluHVNgRO4zZatnL7buz5efHxD/MpKtR59pa7xdHTVsXP9hJ9oDuir Irdb/gjAhFYp6kT97nH5mpSmQ0ZC2ZVI8iJkN8fBGanh+k05NNRbEDsH38MynTRo mLdgCKaevA+d7qQ9sPLEolziHazcdo+6Fw5lm4ypPYIRXaTvn9hSDNVrk6jduD38 Pm6cstiMWF8w63TFQIbwNCGFzVO4pzbP3d9k7DE7fCWrOMVCvzd4Ez4R+p2+R+PD VFkEbnWQT6Jru65sYkQwGZgXQd3HTz6pOO3sMtJdQZaDZ92llx62nc5VeZMQa0/t BDkV8YPLzDooom3JHfEXlea8NmdMjUtNBNZ+VWm9h9SAyxP7I/jllk39hjxioRTN sRAo/fg5gJ3q1azjxi34CcCqW1M0V9ls8BYTBB6SUJ8GYBj6X/Z3iNEciRZiJtKe /9r+olw5y0Y= =7Yu2 -----END PGP SIGNATURE-----