Protect yourself against future threats.
-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA256 =========================================================================== AUSCERT External Security Bulletin Redistribution ESB-2021.1355 Advisory (icsa-21-110-03) Delta Industrial Automation COMMGR 21 April 2021 =========================================================================== AusCERT Security Bulletin Summary --------------------------------- Product: Delta Industrial Automation COMMGR Publisher: ICS-CERT Operating System: Network Appliance Impact/Access: Execute Arbitrary Code/Commands -- Remote/Unauthenticated Denial of Service -- Remote/Unauthenticated Resolution: Patch/Upgrade CVE Names: CVE-2021-27480 Original Bulletin: https://us-cert.cisa.gov/ics/advisories/icsa-21-110-03 - --------------------------BEGIN INCLUDED TEXT-------------------- ICS Advisory (ICSA-21-110-03) Delta Industrial Automation COMMGR Original release date: April 20, 2021 Legal Notice All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/ . 1. EXECUTIVE SUMMARY o CVSS v3 9.8 o ATTENTION: Exploitable remotely/Low attack complexity o Vendor: Delta Industrial Automation o Equipment: COMMGR o Vulnerability: Stack-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of this vulnerability could allow for remote code execution or cause the application to crash, resulting in a denial-of-service condition in the application server. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of COMMGR, a communication management software, and accompanying PLC simulators, are affected: o COMMGR: Version 1.12 and prior 3.2 VULNERABILITY OVERVIEW 3.2.1 STACK-BASED BUFFER OVERFLOW CWE-121 The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to execute remote code. CVE-2021-27480 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is ( AV:N/AC:L/PR:N/UI:N/S:U/ C:H/I:H/A:H ). 3.3 BACKGROUND o CRITICAL INFRASTRUCTURE SECTORS : Commercial Facilities, Communications, Critical Manufacturing, Energy, Healthcare and Public Health o COUNTRIES/AREAS DEPLOYED: Worldwide o COMPANY HEADQUARTERS LOCATION: Taiwan 3.4 RESEARCHER Peter Cheng from CyberSpace Non-Attack Research Institute of Elex CyberSecurity, Inc., reported this vulnerability to CISA. 4. MITIGATIONS Delta Electronics has released COMMGR v1.13 to address this vulnerability and recommends users to upgrade. CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should: o Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet . o Locate control system networks and remote devices behind firewalls and isolate them from the business network. o When remote access is required, use secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices. CISA also recommends users take the following measures to protect themselves from social engineering attacks: o Do not click web links or open unsolicited attachments in email messages. o Refer to Recognizing and Avoiding Email Scam s for more information on avoiding email scams. o Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on us-cert.cisa.gov . Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies . Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies . Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents. No known public exploits specifically target this vulnerability. For any questions related to this report, please contact the CISA at: Email: CISAservicedesk@cisa.dhs.gov Toll Free: 1-888-282-0870 CISA continuously strives to improve its products and services. You can help by choosing one of the links below to provide feedback about this product. - --------------------------END INCLUDED TEXT-------------------- You have received this e-mail bulletin as a result of your organisation's registration with AusCERT. The mailing list you are subscribed to is maintained within your organisation, so if you do not wish to continue receiving these bulletins you should contact your local IT manager. If you do not know who that is, please send an email to auscert@auscert.org.au and we will forward your request to the appropriate person. NOTE: Third Party Rights This security bulletin is provided as a service to AusCERT's members. As AusCERT did not write the document quoted above, AusCERT has had no control over its content. The decision to follow or act on information or advice contained in this security bulletin is the responsibility of each user or organisation, and should be considered in accordance with your organisation's site policies and procedures. AusCERT takes no responsibility for consequences which may arise from following or acting on information or advice contained in this security bulletin. NOTE: This is only the original release of the security bulletin. It may not be updated when updates to the original are made. If downloading at a later date, it is recommended that the bulletin is retrieved directly from the author's website to ensure that the information is still current. Contact information for the authors of the original document is included in the Security Bulletin above. If you have any questions or need further information, please contact them directly. Previous advisories and external security bulletins can be retrieved from: https://www.auscert.org.au/bulletins/ =========================================================================== Australian Computer Emergency Response Team The University of Queensland Brisbane Qld 4072 Internet Email: auscert@auscert.org.au Facsimile: (07) 3365 7031 Telephone: (07) 3365 4417 (International: +61 7 3365 4417) AusCERT personnel answer during Queensland business hours which are GMT+10:00 (AEST). On call after hours for member emergencies only. =========================================================================== -----BEGIN PGP SIGNATURE----- Comment: http://www.auscert.org.au/render.html?it=1967 iQIVAwUBYH+Ku+NLKJtyKPYoAQjQkg/9H9rnojq/sexQxST5Jvb4Pm/c/ZDDPLcp LRtEIT2+D8Pm99Mcpc1dTfiqhD5BLYXl2xdmq5T6w796lSuQlB36CV1y+ht9nWTK JZ0ipky0Ksq0QGO1dsHQSzZZ3fzoTfSqiflGDBzurxCTZnxizkBWvAtx85MHzRLt GOvrTir1O6UuuCZY4yxV49X8dAnAJPB3XN+cyvsKhnC7Uomm2ZgZAiX0TIVfAUZi O886HeB3wF7At1Vojz0rGTIE52Jm1Lr++g10yQFTRGI3HZ08wJQLt79vMoteKPwR gHAnxlmLmHsurm/0PHfeUDy0Y8ER24SeAMuu7cZ0N3vDiLR0HotnPDmnqeDyLeFN w/9hlUE+pnCFDODZDlz4GagfWO2oYRV45Ebf5bwRANdeRntivLGbYkRUUnk9cn6H qAbMpK3F8O9NmRPQ/xoR9MMx5+tu8ZTrjCNhTEM2pB8wz2w41a+jhbGiAhcwlNrJ BMp5v1Nv2ngLpAAqcIToF/MsRuK+7onwbgj2iAI6rfF1173r/OamXymEf6HCAae+ +Bzuaqyog3oWWBdTx/l/tviGXvlvC25LrLQyAtUY/N7eyDb0euOQRMnr1p4ApTHT vQF6730lLH9YCV5vNIZOsmcDtUgw6kZytI356ALW5jePAXhR/HwsjICwMuDmlsqm UGy+6Bd9FIw= =/HBp -----END PGP SIGNATURE-----