Protect yourself against future threats.
-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA256 =========================================================================== AUSCERT External Security Bulletin Redistribution ESB-2021.0678 (icsa-21-054-01) Rockwell Automation FactoryTalk Services Platform 24 February 2021 =========================================================================== AusCERT Security Bulletin Summary --------------------------------- Product: Rockwell Automation FactoryTalk Services Platform Publisher: ICS-CERT Operating System: Network Appliance Windows Impact/Access: Reduced Security -- Remote/Unauthenticated Resolution: Patch/Upgrade CVE Names: CVE-2020-14516 Original Bulletin: https://us-cert.cisa.gov/ics/advisories/icsa-21-054-01 - --------------------------BEGIN INCLUDED TEXT-------------------- ICS Advisory (ICSA-21-054-01) Rockwell Automation FactoryTalk Services Platform Original release date: February 23, 2021 Legal Notice All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/ . 1. EXECUTIVE SUMMARY o CVSS v3 10.0 o ATTENTION: Exploitable remotely/low skill level to exploit o Vendor: Rockwell Automation o Equipment: FactoryTalk Services o Vulnerability: Use of Password Hash with Insufficient Computational Effort 2. RISK EVALUATION Successful exploitation of this vulnerability could allow a remote, unauthenticated attacker to create new users in the FactoryTalk Services Platform administration console. These new users could allow an attacker to modify or delete configuration and application data in other FactoryTalk software connected to the FactoryTalk Services Platform. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS o FactoryTalk Services Platform Versions 6.10.00 and 6.11.00 3.2 VULNERABILITY OVERVIEW 3.2.1 USE OF PASSWORD HASH WITH INSUFFICIENT COMPUTATIONAL EFFORT CWE-916 There is an issue with the implementation of the SHA-256 hashing algorithm with FactoryTalk Services Platform that prevents the user password from being hashed properly. CVE-2020-14516 has been assigned to this vulnerability. A CVSS v3 base score of 10.0 has been assigned; the CVSS vector string is ( AV:N/AC:L/PR:N/UI:N/S:C/C:H /I:H/A:H ). 3.3 BACKGROUND o CRITICAL INFRASTRUCTURE SECTORS: Chemical, Commercial Facilities, Critical Manufacturing, Energy, Government Facilities, Water and Wastewater Systems o COUNTRIES/AREAS DEPLOYED: Worldwide o COMPANY HEADQUARTERS LOCATION: United States 3.4 RESEARCHER Rockwell Automation reported this vulnerability to CISA. 4. MITIGATIONS Rockwell Automation has released a new version of the affected software for download (login required). For more information see the Rockwell Automation security advisory (login required). CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should: o Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet . o Locate control system networks and remote devices behind firewalls, and isolate them from the business network. o When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on us-cert.cisa.gov . Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies . Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies . Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents. No known public exploits specifically target this vulnerability. For any questions related to this report, please contact the CISA at: Email: CISAservicedesk@cisa.dhs.gov Toll Free: 1-888-282-0870 CISA continuously strives to improve its products and services. You can help by choosing one of the links below to provide feedback about this product. - --------------------------END INCLUDED TEXT-------------------- You have received this e-mail bulletin as a result of your organisation's registration with AusCERT. The mailing list you are subscribed to is maintained within your organisation, so if you do not wish to continue receiving these bulletins you should contact your local IT manager. If you do not know who that is, please send an email to auscert@auscert.org.au and we will forward your request to the appropriate person. NOTE: Third Party Rights This security bulletin is provided as a service to AusCERT's members. As AusCERT did not write the document quoted above, AusCERT has had no control over its content. The decision to follow or act on information or advice contained in this security bulletin is the responsibility of each user or organisation, and should be considered in accordance with your organisation's site policies and procedures. AusCERT takes no responsibility for consequences which may arise from following or acting on information or advice contained in this security bulletin. NOTE: This is only the original release of the security bulletin. It may not be updated when updates to the original are made. If downloading at a later date, it is recommended that the bulletin is retrieved directly from the author's website to ensure that the information is still current. Contact information for the authors of the original document is included in the Security Bulletin above. If you have any questions or need further information, please contact them directly. Previous advisories and external security bulletins can be retrieved from: https://www.auscert.org.au/bulletins/ =========================================================================== Australian Computer Emergency Response Team The University of Queensland Brisbane Qld 4072 Internet Email: auscert@auscert.org.au Facsimile: (07) 3365 7031 Telephone: (07) 3365 4417 (International: +61 7 3365 4417) AusCERT personnel answer during Queensland business hours which are GMT+10:00 (AEST). On call after hours for member emergencies only. =========================================================================== -----BEGIN PGP SIGNATURE----- Comment: http://www.auscert.org.au/render.html?it=1967 iQIVAwUBYDW3FONLKJtyKPYoAQi5qw//QRvBsbIX2qjNj1wcx+O2+TL+Y9Shl9Yu 5U6l+CCva4M8eMREKW6tgLLDzpjIHgrUg8LO0rqRWU8PvRT0nkzZd7gjIg6X5TIH DZZnwj3a8g4JMg4L9S0PEVvzHA7Tn3ko9ymnmfO6cOoq8SDYFAHTP3B2rlgtU2gG 1NKKGEMoEczVGdU1fZR96wieb8FLTPjV97CGL1IB0SxrB5mS2TGsxUfq8ff2y41p bYUovzeKfioOIdiaW9xK/JdmDWBB5XnzvKrPWG19fLg8FD/8lHZXzZgHsPzIhKBi ln2q/324gLNZrpmjS8zZypv+rLuqwQgiHyyW8vkP4mzByjmN5XH0AMRYNRPdETrB P2qpXHWr0nvazq8rZlhRiPRR7KebRMqWyU/cJRzFlsA88PB/CDLeypIwdV0/ABFC HUEuDgFhvxauDopQ3h+jIwGjVOhKluUnsOS3tA0MYe3xVDN0G097AzFe/NhWMu0e LtqmZCUIz66wcon7IzeC6UcmP5ScqQMOALM4qpNnnMsEKzAJq1rpue8N1jQh4cVv ii2eU6GID7GnNjw3nfQFUTEYFvPJkBKiwdj2cj5YeEs75cZLyKFQqoqtFlp8HYTS TQhVWqIRluS+ysAuh7wET2L7GkW8tr/ApSZeW+242hCfihODKFSMc8/qflCBRaAV ROsxIVXGikQ= =Bgmd -----END PGP SIGNATURE-----