Protect yourself against future threats.
-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA256 =========================================================================== AUSCERT External Security Bulletin Redistribution ESB-2021.0504 Advisory (icsa-21-040-10) Siemens DIGSI 4 11 February 2021 =========================================================================== AusCERT Security Bulletin Summary --------------------------------- Product: Siemens DIGSI 4 Publisher: ICS-CERT Operating System: Network Appliance Impact/Access: Execute Arbitrary Code/Commands -- Existing Account Increased Privileges -- Existing Account Resolution: Patch/Upgrade CVE Names: CVE-2020-25245 Original Bulletin: https://us-cert.cisa.gov/ics/advisories/icsa-21-040-10 - --------------------------BEGIN INCLUDED TEXT-------------------- ICS Advisory (ICSA-21-040-10) Siemens DIGSI 4 Original release date: February 09, 2021 Legal Notice All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/ . 1. EXECUTIVE SUMMARY o CVSS v3 7.8 o ATTENTION: Low skill level to exploit o Vendor: Siemens o Equipment: DIGSI 4 o Vulnerability: Incorrect Default Permissions 2. RISK EVALUATION Successful exploitation of this vulnerability could allow a low privileged attacker to execute arbitrary code with SYSTEM privileges. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Siemens products are affected: o DIGSI 4: All versions prior to v4.94 SP1 HF 1 3.2 VULNERABILITY OVERVIEW 3.2.1 INCORRECT DEFAULT PERMISSIONS CWE-276 Several folders in the %PATH% are writeable by normal users. As these folders are included in the search for DLLs, an attacker could place a DLL file with code executed by SYSTEM. CVE-2020-25245 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is ( AV:L/AC:L/PR:L/UI:N/S:U/ C:H/I:H/A:H ). 3.3 BACKGROUND o CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing o COUNTRIES/AREAS DEPLOYED: Worldwide o COMPANY HEADQUARTERS LOCATION: Germany 3.4 RESEARCHER Rich Davy from ECSC Group reported this vulnerability to Siemens. 4. MITIGATIONS Siemens has released updates, which are recommended to be applied when possible: o DIGSI 4: Update to v4.94 SP1 HF 1 or later version As a general security measure, Siemens strongly recommends users protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends users configure the environment according to Siemens' operational guidelines for industrial security , and follow the recommendations in the product manuals. Additional information on industrial security by Siemens can be found at: https://www.siemens.com/industrialsecurity For more information see Siemens security advisory SSA-536315 CISA also recommends users take the following measures to protect themselves from social engineering attacks: o Do not click web links or open unsolicited attachments in email messages. o Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. o Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. CISA also provides a section for control systems security recommended practices on the ICS webpage on us-cert.cisa.gov . Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies . Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies . Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents. No known public exploits specifically target this vulnerability. This vulnerability is not exploitable remotely. For any questions related to this report, please contact the CISA at: Email: CISAservicedesk@cisa.dhs.gov Toll Free: 1-888-282-0870 CISA continuously strives to improve its products and services. You can help by choosing one of the links below to provide feedback about this product. - --------------------------END INCLUDED TEXT-------------------- You have received this e-mail bulletin as a result of your organisation's registration with AusCERT. The mailing list you are subscribed to is maintained within your organisation, so if you do not wish to continue receiving these bulletins you should contact your local IT manager. If you do not know who that is, please send an email to auscert@auscert.org.au and we will forward your request to the appropriate person. NOTE: Third Party Rights This security bulletin is provided as a service to AusCERT's members. As AusCERT did not write the document quoted above, AusCERT has had no control over its content. The decision to follow or act on information or advice contained in this security bulletin is the responsibility of each user or organisation, and should be considered in accordance with your organisation's site policies and procedures. AusCERT takes no responsibility for consequences which may arise from following or acting on information or advice contained in this security bulletin. NOTE: This is only the original release of the security bulletin. It may not be updated when updates to the original are made. If downloading at a later date, it is recommended that the bulletin is retrieved directly from the author's website to ensure that the information is still current. Contact information for the authors of the original document is included in the Security Bulletin above. If you have any questions or need further information, please contact them directly. Previous advisories and external security bulletins can be retrieved from: https://www.auscert.org.au/bulletins/ =========================================================================== Australian Computer Emergency Response Team The University of Queensland Brisbane Qld 4072 Internet Email: auscert@auscert.org.au Facsimile: (07) 3365 7031 Telephone: (07) 3365 4417 (International: +61 7 3365 4417) AusCERT personnel answer during Queensland business hours which are GMT+10:00 (AEST). On call after hours for member emergencies only. =========================================================================== -----BEGIN PGP SIGNATURE----- Comment: http://www.auscert.org.au/render.html?it=1967 iQIVAwUBYCTG0+NLKJtyKPYoAQi6FRAAig3BDhvIzV0bgUT0hgAnBpqnFMMAmsX0 kxRdnNunElRI9SS/zYbTxrGFRsIO2qYz092x+nLcnzK/HYv2ZuafFn+QUmFTx+jj +XJH5XAJ+gu8XmvXldUZKX5aj917gGBEgOxgUsF1s4w4y9J993k2wte6H/kO0a4P jTjGF0QrVhKARJcSEBWU/I0I2AyEqaGKz5+b0XrsxQLIXFd2qqdH5oajfhPrLIsO hP7A9s6wvK9h2qELEbzB4JZBL7QLWpXdw/lQJrN7HevJWh7FJyCB0Al1xo2GcSqQ F3CVvw9iTEHGCulyRzC7Ia6wZECiFP8zz22YiHEn9p2uGkv6qmDdQPbW4ibqt+Jc G9jMHr7CYl9kD7QgRXDDEYxzNFt6dqbO9n61rjTTg6QX7Uj0zPBtFgDhiBePU5Gd PFiGeUrso0Y9Tzh++Vky+D8kQ0rIGjRdPi9+QQvXnrQErZ0SuWCCak4OZiTB//UP hv1N5O0wHdIGpwcmM9q3zgVwmlTg3C7pToZDz6jRzD6h+wnCTQltrN6loobai5rv 1SvoZulWYywgDU/FVZBOBgn756wVMBjjqCEwmR6Q6ZCkpgzeGwqMFxizikIaG8mS 3xGjGaMP7rNdMBIPAn4O3la6FzUFq9vDhiFq5Z8DO3hl7BafetOZRwwpbW9qj4MP kXRO+DN4/LE= =qSTD -----END PGP SIGNATURE-----