Protect yourself against future threats.
-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA256 =========================================================================== AUSCERT External Security Bulletin Redistribution ESB-2021.0474 Advisory (icsa-21-040-03) Siemens SINEMA Server & SINEC NMS 10 February 2021 =========================================================================== AusCERT Security Bulletin Summary --------------------------------- Product: Siemens SINEMA Server Siemens SINEC NMS Publisher: ICS-CERT Operating System: Network Appliance Impact/Access: Execute Arbitrary Code/Commands -- Existing Account Resolution: Patch/Upgrade CVE Names: CVE-2020-25237 Original Bulletin: https://us-cert.cisa.gov/ics/advisories/icsa-21-040-03 - --------------------------BEGIN INCLUDED TEXT-------------------- ICS Advisory (ICSA-21-040-03) Siemens SINEMA Server & SINEC NMS Original release date: February 09, 2021 Legal Notice All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/ . 1. EXECUTIVE SUMMARY o CVSS v3 8.8 o ATTENTION: Exploitable remotely/low skill level to exploit o Vendor: Siemens o Equipment: SINEMA Server, SINEC NMS o Vulnerability: Path Traversal 2. RISK EVALUATION Successful exploitation of this vulnerability could allow arbitrary code execution on an affected system. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Siemens products, are affected: o SINEC NMS: All versions prior to v1.0 SP1 Update 1 o SINEMA Server: All versions prior to v14.0 SP2 Update 2 3.2 VULNERABILITY OVERVIEW 3.2.1 IMPROPER LIMITATION OF A PATHNAME TO A RESTRICTED DIRECTORY ('PATH TRAVERSAL') CWE-22 When uploading files to an affected system using a zip container, the system does not correctly check if the relative file path of the extracted files is still within the intended target directory. An attacker could exploit this vulnerability to create or overwrite arbitrary files on an affected system. CVE-2020-25237 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is ( AV:N/AC:L/PR:L/UI:N/S:U/ C:H/I:H/A:H ). 3.3 BACKGROUND o CRITICAL INFRASTRUCTURE SECTORS: Chemical, Energy, Food and Agriculture, Water and Wastewater Systems o COUNTRIES/AREAS DEPLOYED: Worldwide o COMPANY HEADQUARTERS LOCATION: Germany 3.4 RESEARCHER rgod, working with Trend Micro's Zero Day Initiative, reported this vulnerability to CISA. 4. MITIGATIONS Siemens has published security advisory SSA-156833 that further describes how this vulnerability affects SINEC NMS and SINEMA Server . Siemens recommends users update their products to the latest version. Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk: o Restrict access to the affected components to trusted personnel. As a general security measure, Siemens strongly recommends users protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends users configure the environment according to Siemens' operational guidelines for industrial security , and follow the recommendations in the product manual. Additional information on industrial security by Siemens can be found at: https://www.siemens.com/industrialsecurity CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should: o Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet . o Locate control system networks and remote devices behind firewalls, and isolate them from the business network. o When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on us-cert.cisa.gov . Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies . Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies . Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents. No known public exploits specifically target this vulnerability. For any questions related to this report, please contact the CISA at: Email: CISAservicedesk@cisa.dhs.gov Toll Free: 1-888-282-0870 CISA continuously strives to improve its products and services. You can help by choosing one of the links below to provide feedback about this product. - --------------------------END INCLUDED TEXT-------------------- You have received this e-mail bulletin as a result of your organisation's registration with AusCERT. The mailing list you are subscribed to is maintained within your organisation, so if you do not wish to continue receiving these bulletins you should contact your local IT manager. If you do not know who that is, please send an email to auscert@auscert.org.au and we will forward your request to the appropriate person. NOTE: Third Party Rights This security bulletin is provided as a service to AusCERT's members. As AusCERT did not write the document quoted above, AusCERT has had no control over its content. The decision to follow or act on information or advice contained in this security bulletin is the responsibility of each user or organisation, and should be considered in accordance with your organisation's site policies and procedures. AusCERT takes no responsibility for consequences which may arise from following or acting on information or advice contained in this security bulletin. NOTE: This is only the original release of the security bulletin. It may not be updated when updates to the original are made. If downloading at a later date, it is recommended that the bulletin is retrieved directly from the author's website to ensure that the information is still current. Contact information for the authors of the original document is included in the Security Bulletin above. If you have any questions or need further information, please contact them directly. Previous advisories and external security bulletins can be retrieved from: https://www.auscert.org.au/bulletins/ =========================================================================== Australian Computer Emergency Response Team The University of Queensland Brisbane Qld 4072 Internet Email: auscert@auscert.org.au Facsimile: (07) 3365 7031 Telephone: (07) 3365 4417 (International: +61 7 3365 4417) AusCERT personnel answer during Queensland business hours which are GMT+10:00 (AEST). On call after hours for member emergencies only. =========================================================================== -----BEGIN PGP SIGNATURE----- Comment: http://www.auscert.org.au/render.html?it=1967 iQIVAwUBYCN9M+NLKJtyKPYoAQhTsw//QT4OSD/qPH3HUVSnDjKQabay3o1BU5cM 9Kvjvobwg45pTneZ2yC5utvXtDq6MzRTNYq/cfs9847vbATsqENgc7x6gtFeKgxZ WF4PFoKY9mcZ9a28QQiN/grZIM9snfQRB6IHABpCVpBi6ToexZ2DE9Yz2wqsCBem VKlWa52xS5DnL3Djjsi0RrGnIZ8LebXdknvQqhknaKmkbThSJYemg0+14+N9SPy6 Zph0BdYZPDF7Dqm1pDPZw8tfH4OpHjo/K4gYsI0VVikdWHi6HWCdBuU//QQLMb9u BopH+L9O5ypZFHPTxKnNSnDloRLUiVTKFK6wkFyazF0G990rZkjZoccNPLes0x9R CKb3Nyne4fiBTh/UfeGgsUe5NIi2M9oLh7iUjg2D/EH6scEl0diCUnrdLW1nxGle 1cN0lXDjeTSve8AfFkKtY9UY4Zb2uctDcWnC/UI18ML8ovhjuS4Js6D/KD+yES65 z9T3j/guzTWnKbGvdijJZBerjzAp+7/uFhbV7sL7KpgoOixz9/X9dEsrEtcQEQk5 goWmrAVaRjfMvDM0baWTLFQpQOEZjTEnUbq/kaHm6+S/G+YJ6qg5VTByBYjFsxT+ UQy0ZYfc3KznNYrecQTXHdmvMPuMhY53rdrJwlfc4BV8WVg6az3/cGHcXOPQ9vBt Oo24TBH3GGE= =O5Oi -----END PGP SIGNATURE-----