Protect yourself against future threats.
-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA256 =========================================================================== AUSCERT External Security Bulletin Redistribution ESB-2020.2210 Multiple Rockwell FactoryTalk Vulnerabilities 26 June 2020 =========================================================================== AusCERT Security Bulletin Summary --------------------------------- Product: Rockwell FactoryTalk Publisher: US-CERT Operating System: Network Appliance Impact/Access: Denial of Service -- Existing Account Access Confidential Data -- Existing Account Resolution: Patch/Upgrade CVE Names: CVE-2020-14481 CVE-2020-14480 Original Bulletin: https://www.us-cert.gov/ics/advisories/icsa-20-177-03 https://www.us-cert.gov/ics/advisories/icsa-20-177-02 Comment: This bulletin contains two (2) security advisories. - --------------------------BEGIN INCLUDED TEXT-------------------- ICS Advisory (ICSA-20-177-03) Rockwell FactoryTalk View SE Original release date: June 25, 2020 Legal Notice All information products included in https://us-cert.gov/ics are provided"as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://www.us-cert.gov/tlp/ . 1. EXECUTIVE SUMMARY o CVSS v3 8.8 o ATTENTION: Low skill level to exploit o Vendor: Rockwell Automation o Equipment: FactoryTalk View SE o Vulnerabilities: Cleartext Storage of Sensitive Information, Weak Encoding for Password 2. RISK EVALUATION Successful exploitation of these vulnerabilities could lead to unauthorized access to server data. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of FactoryTalk View SE are affected: o FactoryTalk View SE Versions 9.0 and earlier o FactoryTalk View SE Version 10.0 3.2 VULNERABILITY OVERVIEW 3.2.1 CLEARTEXT STORAGE OF SENSITIVE INFORMATION CWE-312 Due to usernames/passwords being stored in plaintext in Random Access Memory (RAM), a local, authenticated attacker could gain access to certain credentials, including Windows Logon credentials. CVE-2020-14480 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been assigned; the CVSS vector string is ( AV:L/AC:L/PR:L/UI:N/S:C/C:H/ I:H/A:H ). 3.2.2 WEAK ENCODING FOR PASSWORD CWE-261 The DeskLock tool provided with FactoryTalk View SE uses a weak encryption algorithm that may allow a local, authenticated attacker to decipher user credentials, including the Windows user or Windows DeskLock passwords. If the compromised user has an administrative account, an attacker could gain full access to the user's operating system and certain components of FactoryTalk View SE. CVE-2020-14481 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been assigned; the CVSS vector string is ( AV:L/AC:L/PR:L/UI:N/S:C/C:H/ I:H/A:H ). 3.3 BACKGROUND o CRITICAL INFRASTRUCTURE SECTORS: Chemical, Commercial Facilities, Critical Manufacturing, Energy, Government Facilities, Water and Wastewater Systems o COUNTRIES/AREAS DEPLOYED: Worldwide o COMPANY HEADQUARTERS LOCATION: United States 3.4 RESEARCHER Ilya Karpov and Evgeny Druzhinin, who are part of the independent research team ScadaX Security, reported these vulnerabilities to Rockwell. 4. MITIGATIONS Users of the affected versions of DeskLock provided with FactoryTalk View SE are encouraged to update to an available software version that addresses the associated risk, v10.0 or later. Users who are unable to update are directed towards risk mitigation strategies provided below, and are encouraged, when possible, to combine these with the general security guidelines to employ multiple strategies simultaneously. CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should: o Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet . o Locate control system networks and remote devices behind firewalls, and isolate them from the business network. o When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on us-cert.gov . Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies . Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies . Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents. No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely. For any questions related to this report, please contact the CISA at: Email: CISAservicedesk@cisa.dhs.gov Toll Free: 1-888-282-0870 CISA continuously strives to improve its products and services. You can help by choosing one of the links below to provide feedback about this product. - ------------------------------------------------------------------------------- ICS Advisory (ICSA-20-177-02) Rockwell FactoryTalk Services Platform XXE Original release date: June 25, 2020 Legal Notice All information products included in https://us-cert.gov/ics are provided"as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://www.us-cert.gov/tlp/ . 1. EXECUTIVE SUMMARY o CVSS v3 8.4 o ATTENTION: Low skill level to exploit o Vendor: Rockwell Automation o Equipment: FactoryTalk Services Platform o Vulnerability: Improper Restriction of XML External Entity Reference 2. RISK EVALUATION Successful exploitation of this vulnerability could lead to a denial-of-service condition and to the arbitrary reading of any local file via system level services. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of FactoryTalk Services Platform are affected: o Versions 6.11.00 and earlier 3.2 VULNERABILITY OVERVIEW 3.2.1 IMPROPER RESTRICTION OF XML EXTERNAL ENTITY REFERENCE CWE-611 A remote, unauthenticated attacker could use an XML External Entity (XXE) attack to exploit weakly configured XML files to access local or remote content. A successful exploit could potentially cause a denial-of-service condition and allow the attacker to arbitrarily read any local file via system-level services. CVE-2020-14478 has been assigned to this vulnerability. A CVSS v3 base score of 8.4 has been assigned; the CVSS vector string is ( AV:L/AC:L/PR:L/UI:N/S:C/C:H/ I:N/A:H ). 3.3 BACKGROUND o CRITICAL INFRASTRUCTURE SECTORS: Food and Agriculture, Transportation Systems, Water and Wastewater Systems o COUNTRIES/AREAS DEPLOYED: Worldwide o COMPANY HEADQUARTERS LOCATION: United States 3.4 RESEARCHER Applied Risk reported this vulnerability to Rockwell. 4. MITIGATIONS Affected users are encouraged to use Rockwell Automation Knowledgebase article 25612 to determine if FactoryTalk Services Platform is installed. For more information please see Rockwell Automation Knowledgebase article 1092746 CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should: CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should: o Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet . o Locate control system networks and remote devices behind firewalls, and isolate them from the business network. o When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on us-cert.gov . Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies . Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies . Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents. No known public exploits specifically target this vulnerability. This vulnerability is not exploitable remotely. For any questions related to this report, please contact the CISA at: Email: CISAservicedesk@cisa.dhs.gov Toll Free: 1-888-282-0870 CISA continuously strives to improve its products and services. You can help by choosing one of the links below to provide feedback about this product. - --------------------------END INCLUDED TEXT-------------------- You have received this e-mail bulletin as a result of your organisation's registration with AusCERT. The mailing list you are subscribed to is maintained within your organisation, so if you do not wish to continue receiving these bulletins you should contact your local IT manager. If you do not know who that is, please send an email to auscert@auscert.org.au and we will forward your request to the appropriate person. NOTE: Third Party Rights This security bulletin is provided as a service to AusCERT's members. As AusCERT did not write the document quoted above, AusCERT has had no control over its content. The decision to follow or act on information or advice contained in this security bulletin is the responsibility of each user or organisation, and should be considered in accordance with your organisation's site policies and procedures. AusCERT takes no responsibility for consequences which may arise from following or acting on information or advice contained in this security bulletin. NOTE: This is only the original release of the security bulletin. It may not be updated when updates to the original are made. If downloading at a later date, it is recommended that the bulletin is retrieved directly from the author's website to ensure that the information is still current. Contact information for the authors of the original document is included in the Security Bulletin above. If you have any questions or need further information, please contact them directly. Previous advisories and external security bulletins can be retrieved from: https://www.auscert.org.au/bulletins/ =========================================================================== Australian Computer Emergency Response Team The University of Queensland Brisbane Qld 4072 Internet Email: auscert@auscert.org.au Facsimile: (07) 3365 7031 Telephone: (07) 3365 4417 (International: +61 7 3365 4417) AusCERT personnel answer during Queensland business hours which are GMT+10:00 (AEST). On call after hours for member emergencies only. =========================================================================== -----BEGIN PGP SIGNATURE----- Comment: http://www.auscert.org.au/render.html?it=1967 iQIVAwUBXvVSm+NLKJtyKPYoAQhpYw/+PAigk9hGS7hwm3oDvRhNVvi8QfQ/TVs8 NXPQ7WYcDZmu/JfKYXb9FcIIhNSftpX4SjyR2wicnktTgHlN7+LAQx4LXGi6NXIP eFxKlcfgfY+F0uHSoHajFZZuyKtW4KVu/TJyf6BK7GvHrLyQEN+tkOHNkE/7VFqR +LWXwZbZlMTGR30TX8pwysLntuLuI6zdooV05zEas8Eff7GdaXwx0/MgXsZAvR7d yQPJ5k5+D0MMdA2ynLJfz4U9c+DtmJ/y6nEWBJCGtUtngOxnPr44D3lTEtd8NU+2 G+4yu4sBgIKAgPF4XyuzJ4+Wqz5V/2QyR83XByenTQNkFvJEVIl5BHNaFpIrKyA6 A29QrJ2ZIJ6ZeJlm1GHrGvs+5KBaq5J0yzc28lTqbcDQYokyWcB7bVA0kUDwQ5xU lNwkvSpQxJr9+gCLL5qAecJYT3HbvOTUYN2QV/oWyW1xHmad1Y1c2dmDJktntbHl pZ3ffF9Hm4sMs2B0Ury8GnwmLsgPqHu/K9L6oQz5+boTDSOoBfK2XtmQF3YFrCl6 wsduGuNdJpfxguUeJGIPObUrZAs2nm5iTaogfolvtLsWsjRL3+oRuGrgQtV6AwPo lswaoN3q52hsw37xarMdocBkCsEMIjWiuXqZlPBOK4kpJV4dH11ngEc4VoGFDmEg aj0bNnG6HkA= =ca6+ -----END PGP SIGNATURE-----