Protect yourself against future threats.
-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA256 =========================================================================== AUSCERT External Security Bulletin Redistribution ESB-2020.2148 Advisory (icsa-20-170-01) Johnson Controls exacqVision 22 June 2020 =========================================================================== AusCERT Security Bulletin Summary --------------------------------- Product: Johnson Controls exacqVision Publisher: US-CERT Operating System: Network Appliance Impact/Access: Execute Arbitrary Code/Commands -- Remote with User Interaction Resolution: Patch/Upgrade CVE Names: CVE-2020-9047 Original Bulletin: https://www.us-cert.gov/ics/advisories/icsa-20-170-01 - --------------------------BEGIN INCLUDED TEXT-------------------- ICS Advisory (ICSA-20-170-01) Johnson Controls exacqVision Original release date: June 18, 2020 Legal Notice All information products included in https://us-cert.gov/ics are provided"as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://www.us-cert.gov/tlp/ . 1. EXECUTIVE SUMMARY o CVSS v3 6.8 o ATTENTION: Exploitable remotely o Vendor: Exacq Technologies, a subsidiary of Johnson Controls o Equipment: exacqVision o Vulnerability: Improper Verification of Cryptographic Signature 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker with administrative privileges to potentially download and run a malicious executable that could allow the execution of operating system commands on the system. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Johnson Controls reports the vulnerability affects the following exacqVision products: o exacqVision Web Service: All versions up to and including v20.03.2.0 o exacqVision Enterprise Manager: All versions up to and including v20.03.3.0 3.2 VULNERABILITY OVERVIEW 3.2.1 IMPROPER VERIFICATION OF CRYPTOGRAPHIC SIGNATURE CWE-347 The software does not verify the cryptographic signature for data, which could allow an attacker with administrative privileges to download and run a malicious executable. CVE-2020-9047 has been assigned to this vulnerability. A CVSS v3 base score of 6.8 has been calculated; the CVSS vector string is ( AV:N/AC:H/PR:H/UI:R/S:C/ C:L/I:H/A:L ). 3.3 BACKGROUND o CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing o COUNTRIES/AREAS DEPLOYED: Worldwide o COMPANY HEADQUARTERS LOCATION: Ireland 3.4 RESEARCHER Michael Norris reported this vulnerability to Johnson Controls. 4. MITIGATIONS Johnson Controls recommends the following mitigations: o Upgrade exacqVision Web Service to v20.06.2.0 or higher o Upgrade exacqVision Enterprise Manager to v20.06.3.0 or higher For more detailed mitigation instructions, please see Johnson Controls Product Security Advisory JCI-PSA-2020-7 v1 Johnson Controls recommends taking steps to minimize risks to all building automation systems. CISA recommends users take the following measures to protect themselves from social engineering attacks: o Ensure the least-privilege user principle is followed. o Do not click web links or open unsolicited attachments in email messages. o Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. o Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on us-cert.gov . Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies . Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies . Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents. No known public exploits specifically target this vulnerability. High skill level is needed to exploit. For any questions related to this report, please contact the CISA at: Email: CISAservicedesk@cisa.dhs.gov Toll Free: 1-888-282-0870 CISA continuously strives to improve its products and services. You can help by choosing one of the links below to provide feedback about this product. - --------------------------END INCLUDED TEXT-------------------- You have received this e-mail bulletin as a result of your organisation's registration with AusCERT. The mailing list you are subscribed to is maintained within your organisation, so if you do not wish to continue receiving these bulletins you should contact your local IT manager. If you do not know who that is, please send an email to auscert@auscert.org.au and we will forward your request to the appropriate person. NOTE: Third Party Rights This security bulletin is provided as a service to AusCERT's members. As AusCERT did not write the document quoted above, AusCERT has had no control over its content. The decision to follow or act on information or advice contained in this security bulletin is the responsibility of each user or organisation, and should be considered in accordance with your organisation's site policies and procedures. AusCERT takes no responsibility for consequences which may arise from following or acting on information or advice contained in this security bulletin. NOTE: This is only the original release of the security bulletin. It may not be updated when updates to the original are made. If downloading at a later date, it is recommended that the bulletin is retrieved directly from the author's website to ensure that the information is still current. Contact information for the authors of the original document is included in the Security Bulletin above. If you have any questions or need further information, please contact them directly. Previous advisories and external security bulletins can be retrieved from: https://www.auscert.org.au/bulletins/ =========================================================================== Australian Computer Emergency Response Team The University of Queensland Brisbane Qld 4072 Internet Email: auscert@auscert.org.au Facsimile: (07) 3365 7031 Telephone: (07) 3365 4417 (International: +61 7 3365 4417) AusCERT personnel answer during Queensland business hours which are GMT+10:00 (AEST). On call after hours for member emergencies only. =========================================================================== -----BEGIN PGP SIGNATURE----- Comment: http://www.auscert.org.au/render.html?it=1967 iQIVAwUBXvAY+uNLKJtyKPYoAQgKkhAAhnTi7zr+Lbr0HyERHaKreWeTmQsY/tVQ VYXMmdYqf6fRb2IBaPoHy/Joz5+7+4lnnwFkLpHRtAhA7pyGZNgsPQ3PXj4t1FCj 9sbC6J1oDSmiLg8D11/C/SS33w7daFmtG4smT1fhSqrL4hZ6nq01Je8ciHXthfko R8r7Zx7vfBlUMyYF5mnZEpBM2GVAYZ+0jI8Xy2BdDWfRvkb/BbiqY/O58/r3pcin ZiTCn0N8aHFzHA+Uz/FUn/xOBjKZ4CuTZkpw3/dAffmZAiYRy8D70L17ZuNeRqP/ z130HWb89Dp0Tfbz3XBpU5CHyITehVEb5Au+OODaMQ+RwtZEjXIF2TCVyOLeBwQm Y62oE+2jnbAr9R9RY6yJqqGFTuQqKmrdJuIpMniEKPaRkAxlbYNTOsRrDEmw4Lnd Y6t8VN/vGcaHMxNzl6SzUPFOZK8qiCz8H1KhVloZjqEmYdq6uHNACmDa4o1wUa+F hJCXPPPBmyV0Id7Qa2zc320V7kuR666iu90TYRGvCGBcnl7PmByC8/PhvlxTlPxb mom1776bRSAT2QXVwvY3LRIFLsvKl4DKI1PurAbaFSKUOTnchY2Evf+28IQOmJ0t mYqT07rL0ag9J6jjttGqPVmUj7SEmDYFeCP8y/jYf+dkUDtfb/4ynF6w3p8hx8rs jCR8qJNJoso= =nwsg -----END PGP SIGNATURE-----