Protect yourself against future threats.
-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA256 =========================================================================== AUSCERT External Security Bulletin Redistribution ESB-2020.2062 ICS Advisory (ICSA-20-163-02) Rockwell Automation FactoryTalk Linx Software 15 June 2020 =========================================================================== AusCERT Security Bulletin Summary --------------------------------- Product: Rockwell Automation FactoryTalk Linx Rockwell Automation RSLinx Classic Publisher: ICS-CERT Operating System: Network Appliance Impact/Access: Execute Arbitrary Code/Commands -- Existing Account Modify Arbitrary Files -- Existing Account Denial of Service -- Remote/Unauthenticated Access Confidential Data -- Remote/Unauthenticated Resolution: Patch/Upgrade CVE Names: CVE-2020-12005 CVE-2020-12003 CVE-2020-12001 CVE-2020-11999 Original Bulletin: https://www.us-cert.gov/ics/advisories/icsa-20-163-02 - --------------------------BEGIN INCLUDED TEXT-------------------- ICS Advisory (ICSA-20-163-02) Rockwell Automation FactoryTalk Linx Software Original release date: June 11, 2020 Legal Notice All information products included in https://us-cert.gov/ics are provided"as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://www.us-cert.gov/tlp/ . 1. EXECUTIVE SUMMARY o CVSS v3 9.6 o ATTENTION: Exploitable remotely/low skill level to exploit o Vendor: Rockwell Automation o Equipment: FactoryTalk Linx Software o Vulnerabilities: Improper Input Validation, Path Traversal, Unrestricted Upload of File with Dangerous Type 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to cause a denial-of-service condition, obtain remote code execution, and read sensitive information. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following products are affected: o FactoryTalk Linx versions 6.00, 6.10, and 6.11 o RSLinx Classic v4.11.00 and prior The following products that utilize FactoryTalk Linx Software are affected: o Connected Components Workbench: Version 12 and prior o ControlFLASH: Version 14 and later o ControlFLASH Plus: Version 1 and later o FactoryTalk Asset Centre: Version 9 and later o FactoryTalk Linx CommDTM: Version 1 and later o Studio 5000 Launcher: Version 31 and later o Studio 5000 Logix Designer software: Version 32 and prior 3.2 VULNERABILITY OVERVIEW 3.2.1 IMPROPER INPUT VALIDATION CWE-20 An exposed API call allows users to provide files to be processed without sanitation. This may allow an attacker to specify a filename to execute unauthorized code and modify files or data. CVE-2020-11999 has been assigned to this vulnerability. A CVSS v3 base score of 9.6 has been calculated; the CVSS vector string is ( AV:N/AC:L/PR:L/UI:N/S:C/ C:H/I:H/A:N ). 3.2.2 IMPROPER INPUT VALIDATION CWE-20 The parsing mechanism that processes certain file types does not provide input sanitation. This may allow an attacker to use specially crafted files to traverse the file system and modify or expose sensitive data or execute arbitrary code. CVE-2020-12001 has been assigned to this vulnerability. A CVSS v3 base score of 9.6 has been calculated; the CVSS vector string is ( AV:N/AC:L/PR:L/UI:N/S:C/ C:H/I:H/A:N ). 3.2.3 IMPROPER LIMITATION OF A PATHNAME TO A RESTRICTED DIRECTORY ('PATH TRAVERSAL') CWE-22 An exposed API call allows users to provide files to be processed without sanitation. This may allow an attacker to use specially crafted requests to traverse the file system and expose sensitive data on the local hard drive. CVE-2020-12003 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is ( AV:N/AC:L/PR:N/UI:N/S:U/ C:H/I:N/A:N ). 3.2.4 UNRESTRICTED UPLOAD OF FILE WITH DANGEROUS TYPE CWE-434 A vulnerability exists in the communication function that enables users to upload EDS files by FactoryTalk Linx. This may allow an attacker to upload a file with bad compression, consuming all the available CPU resources, leading to a denial-of-service condition. CVE-2020-12005 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is ( AV:N/AC:L/PR:N/UI:N/S:U/ C:N/I:N/A:H ). 3.3 BACKGROUND o CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing, Energy, Water and Wastewater Systems o COUNTRIES/AREAS DEPLOYED: Worldwide o COMPANY HEADQUARTERS LOCATION: United States 3.4 RESEARCHER Sharon Brizinov and Amir Preminger (VP Research) of Claroty reported these vulnerabilities to Rockwell Automation and CISA. 4. MITIGATIONS Rockwell Automation recommends users apply these patches by following instructions in knowledgebase articles below: o Patch Roll-up for CPR9 SRx (Login Required) o FactoryTalk Linx/Services patch RAID# 1124820 (Login Required) o FactoryTalk Linx patch RAID# 1126433 (Login Required) Network-based vulnerability mitigations for embedded products: o Block all traffic to EtherNet/IP or other CIP protocol-based devices from outside the manufacturing zone by blocking or restricting access to TCP Ports 2222, 7153, and UDP Port 44818 using proper network infrastructure controls, such as firewalls, UTM devices, or other security appliances. For more information on TCP/UDP ports used by Rockwell Automation products, see Knowledgebase Article ID 898270 General mitigations: o Locate control system networks and devices behind firewalls and isolate them from the business network. o When remote access is required, use secure methods, such as virtual private networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices. For more information, please refer to Rockwell Automation's security advisory: 54102-Industrial Security Advisory Index . CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on us-cert.gov . Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies . Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies . Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents. No known public exploits specifically target these vulnerabilities. For any questions related to this report, please contact the CISA at: Email: CISAservicedesk@cisa.dhs.gov Toll Free: 1-888-282-0870 CISA continuously strives to improve its products and services. You can help by choosing one of the links below to provide feedback about this product. - --------------------------END INCLUDED TEXT-------------------- You have received this e-mail bulletin as a result of your organisation's registration with AusCERT. The mailing list you are subscribed to is maintained within your organisation, so if you do not wish to continue receiving these bulletins you should contact your local IT manager. If you do not know who that is, please send an email to auscert@auscert.org.au and we will forward your request to the appropriate person. NOTE: Third Party Rights This security bulletin is provided as a service to AusCERT's members. As AusCERT did not write the document quoted above, AusCERT has had no control over its content. The decision to follow or act on information or advice contained in this security bulletin is the responsibility of each user or organisation, and should be considered in accordance with your organisation's site policies and procedures. AusCERT takes no responsibility for consequences which may arise from following or acting on information or advice contained in this security bulletin. NOTE: This is only the original release of the security bulletin. It may not be updated when updates to the original are made. If downloading at a later date, it is recommended that the bulletin is retrieved directly from the author's website to ensure that the information is still current. Contact information for the authors of the original document is included in the Security Bulletin above. If you have any questions or need further information, please contact them directly. Previous advisories and external security bulletins can be retrieved from: https://www.auscert.org.au/bulletins/ =========================================================================== Australian Computer Emergency Response Team The University of Queensland Brisbane Qld 4072 Internet Email: auscert@auscert.org.au Facsimile: (07) 3365 7031 Telephone: (07) 3365 4417 (International: +61 7 3365 4417) AusCERT personnel answer during Queensland business hours which are GMT+10:00 (AEST). On call after hours for member emergencies only. =========================================================================== -----BEGIN PGP SIGNATURE----- Comment: http://www.auscert.org.au/render.html?it=1967 iQIVAwUBXubdfONLKJtyKPYoAQim4g/+NiKb1NtBkrgX5CKTBz1/lCkABenEZLG8 TYRSt0UaVDgQ9g6eHsjo88GP63ZEwbxZrkxKAZ66ibp0rxH5Qvfz3ggFvzbqnlQt Dr/wj+i/9FX5v1Gqk3LrBoxvtvWDDChSUPn+h8dA++9B4jin00ABGubT4/0DOSzu 9bcxDya3HtPbAY/brFwDJH09WtuFVl/eNuDSbhtijR6gFPgj/pKy93KGDAmCgAXG 8m/EPQsTFh3sJ7r4dnjue/fAz5LsULrwbwU9KZ7HoWSVrQ5RFAJZKUDP7i4M9r52 e0ZRlwL1c8kFfVO7OGmu/AmYs0YXW323tK7CPoSOUOzAWFCDOloi9ZpMpz7mKTwe VNN98rRju1AlKHyBzut30mJxADm4dflkGBut7Ctbe/xbW04uxTRjOC+f6NWzaANb RbbacfF/54ykmbaDqFi7ll1Jrdg3RHHrc1lkxY/rECmHR0mh5jIp96Intk8l8sb1 HdMEjlzzSQqJCoeUzBTdE0Lx+usRLu2dLNbZJpawkZSZ6tin+Kuz2xd2mXXyDGrV mSO/kmpsh1PCsRmGD+ZT9Era8ahWCsYd6wApWiO2JTkqguVuUgHK2j2GUxp9LoPs P67TZ3WC5tGkN0NxEodkf7FyCXvG70auodi8lFeIAc5L2S8vrpUz+E6WKdkluLbV MLayWXnr5Ts= =6x+R -----END PGP SIGNATURE-----