Protect yourself against future threats.
-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA256 =========================================================================== AUSCERT External Security Bulletin Redistribution ESB-2019.4313 Advisory (icsa-19-318-03) Siemens Desigo PX Devices 15 November 2019 =========================================================================== AusCERT Security Bulletin Summary --------------------------------- Product: Siemens Desigo PX Publisher: ICS-CERT Operating System: Network Appliance Impact/Access: Denial of Service -- Remote/Unauthenticated Resolution: Patch/Upgrade CVE Names: CVE-2019-13927 Original Bulletin: https://www.us-cert.gov/ics/advisories/icsa-19-318-03 - --------------------------BEGIN INCLUDED TEXT-------------------- ICS Advisory (ICSA-19-318-03) Siemens Desigo PX Devices Original release date: November 14, 2019 Legal Notice All information products included in http://ics-cert.us-cert.gov are provided"as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see http://www.us-cert.gov/tlp/ . 1. EXECUTIVE SUMMARY o CVSS v35.3 o ATTENTION : Exploitable remotely/low skill level to exploit o Vendor : Siemens o Equipment : Desigo PX Devices o Vulnerability : External Control of Assumed-Immutable Web Parameter 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition on the device's web server, requiring a reboot to recover the web interface. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Desigo PX automation controllers are affected: o PXC00-E.D, PXC50-E.D, PXC100-E.D, PXC200-E.D with Desigo PX Web modules PXA40-W0, PXA40-W1, PXA40-W2: All firmware versions prior to V6.00.320 o PXC00-U, PXC64-U, PXC128-U with Desigo PX Web modules PXA30-W0, PXA30-W1, PXA30-W2: All firmware versions prior to V6.00.320 o PXC22.1-E.D, PXC36-E.D, PXC36.1-E.D with activated web server: All firmware versions prior to V6.00.320 3.2 VULNERABILITY OVERVIEW 3.2.1 EXTERNAL CONTROL OF ASSUMED-IMMUTABLE WEB PARAMETER CWE-472 An attacker with network access to an affected device could send a specially crafted HTTP message to the web server port (TCP/80), which would cause the server to reply with status code 404 to any further requests. Exploitation requires no system privileges and no user interaction. A reboot is required to recover the web interface. This vulnerability may impact the availability of the affected system. CVE-2019-13927 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is ( AV:N/AC:L/PR:N/UI:N/S:U/ C:N/I:N/A:L ). 3.3 BACKGROUND o CRITICAL INFRASTRUCTURE SECTORS : Chemical, Critical Manufacturing, Energy, Food and Agriculture, Water and Wastewater Systems o COUNTRIES/AREAS DEPLOYED : Worldwide o COMPANY HEADQUARTERS LOCATION : Germany 3.4 RESEARCHER Gjoko "LiquidWorm" Krstic from Zero Science Lab (MK) reported this vulnerability to Siemens. 4. MITIGATIONS Siemens has an update available for the following affected products: o PXC00-E.D, PXC50-E.D, PXC100-E.D, PXC200-E.D with Desigo PX Web modules PXA40-W0, PXA40-W1, PXA40-W2: Install v6.00.320 or a later version . o PXC00-U, PXC64-U, PXC128-U with Desigo PX Web modules PXA30-W0, PXA30-W1, PXA30-W2: Install v6.00.320 or a later version . o PXC22.1-E.D, PXC36-E.D, PXC36.1-E.D with activated web server: Install v6.00.320 or a later version . Siemens has identified the following specific workarounds and mitigations that users can apply to reduce risk: o Ensure the PX Web interface is accessible only from trusted networks. As a general security measure, Siemens strongly recommends customers protect network access to affected products with appropriate mechanisms. Siemens advises all users to follow recommended security practices to run the devices in a protected environment. For more information on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: http://www.siemens.com/cert/advisories For more information on the vulnerability and more detailed mitigation instructions, please see Siemens Security Advisory SSA-898181 at the following location: http://www.siemens.com/cert/advisories CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should: o Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet . o Locate control system networks and remote devices behind firewalls, and isolate them from the business network. o When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on us-cert.gov . Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies . Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies . Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents. No known public exploits specifically target this vulnerability. - --------------------------END INCLUDED TEXT-------------------- You have received this e-mail bulletin as a result of your organisation's registration with AusCERT. The mailing list you are subscribed to is maintained within your organisation, so if you do not wish to continue receiving these bulletins you should contact your local IT manager. If you do not know who that is, please send an email to auscert@auscert.org.au and we will forward your request to the appropriate person. NOTE: Third Party Rights This security bulletin is provided as a service to AusCERT's members. As AusCERT did not write the document quoted above, AusCERT has had no control over its content. The decision to follow or act on information or advice contained in this security bulletin is the responsibility of each user or organisation, and should be considered in accordance with your organisation's site policies and procedures. AusCERT takes no responsibility for consequences which may arise from following or acting on information or advice contained in this security bulletin. NOTE: This is only the original release of the security bulletin. It may not be updated when updates to the original are made. If downloading at a later date, it is recommended that the bulletin is retrieved directly from the author's website to ensure that the information is still current. Contact information for the authors of the original document is included in the Security Bulletin above. If you have any questions or need further information, please contact them directly. Previous advisories and external security bulletins can be retrieved from: https://www.auscert.org.au/bulletins/ =========================================================================== Australian Computer Emergency Response Team The University of Queensland Brisbane Qld 4072 Internet Email: auscert@auscert.org.au Facsimile: (07) 3365 7031 Telephone: (07) 3365 4417 (International: +61 7 3365 4417) AusCERT personnel answer during Queensland business hours which are GMT+10:00 (AEST). On call after hours for member emergencies only. =========================================================================== -----BEGIN PGP SIGNATURE----- Comment: http://www.auscert.org.au/render.html?it=1967 iQIVAwUBXc4Gb2aOgq3Tt24GAQhX5Q//fA54bX8GUFumJiOESvJrmrk0ZG56vKHZ AbAFuHPUCT5MvXoHgQfN/taTz9PRchSHeHxOCPjKcgeyEKkkLLWTa/IZJdwu/UP0 3rBUYZm3V8C+UvQ++4kipMXUmAxGc+tzAIRrTHbDtub4l96sKgv24tU3sSMN24hx LItn9Vojk04BqwlCOPzWU3+Uy+QP1MvLo2II23y2qFZZcdmXQU5yMK+IwsLo/n1B t2XHbMw7/AN31Tcc71PWiBnmppuXvNDuscteQ1RuWTzKg37ebnnZFexC7AjeYN5U EiHiAeIbj0lMPZmGi1lTUbTtu6qStkQH9uol86trHvvoOVqoCLtTmOcI99kjN49S 27LYuDXm7v3+psovHrhyu6ckkN7YTn8H+es6IYRMjVbZEnsjLEiqVV8rrISyXWcx FvmZ361QBnR2sL9plRIxTgfauF3PBjWxdhSCyQN69KBSKxA5s0GtnfF+gO+0Nt2G C75lP5gJwVqzpTTMmd7ugcUMCuxsgrKFp+7PxXAqyW/WQxRBD0tebdNhcSUgORmH qNX8o4aXTEFLqrvehOM0HehpPDlptFPYVo4xRvxiAdnyfXRFge3Wd2VfdhrustPY ONFunxuspqFXCM3SUiC7Qy0Dpj4BJvNFwYyMCldR9O4diQqcV1UNQo4EFe0V6xnh emrWOu+Yr+E= =5MUe -----END PGP SIGNATURE-----