Protect yourself against future threats.
-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA256 =========================================================================== AUSCERT External Security Bulletin Redistribution ESB-2019.3813.3 Advisory (icsa-19-283-02) Siemens PROFINET Devices 16 January 2020 =========================================================================== AusCERT Security Bulletin Summary --------------------------------- Product: Siemens PROFINET Devices Publisher: ICS-CERT Operating System: Network Appliance Impact/Access: Denial of Service -- Remote/Unauthenticated Resolution: Patch/Upgrade CVE Names: CVE-2019-10936 Original Bulletin: https://www.us-cert.gov/ics/advisories/icsa-19-283-02 Revision History: January 16 2020: Source updated to clarify affected products and specific safe versions for each November 15 2019: Updated affected products October 11 2019: Initial Release - --------------------------BEGIN INCLUDED TEXT-------------------- ICS Advisory (ICSA-19-283-02) Siemens PROFINET Devices (Update B) Original release date: January 14, 2020 Legal Notice All information products included in http://ics-cert.us-cert.gov are provided"as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see http://www.us-cert.gov/tlp/ . 1. EXECUTIVE SUMMARY o CVSS v3 7.5 o ATTENTION: Exploitable remotely/low skill level to exploit o Vendor: Siemens o Equipment: PROFINET Devices o Vulnerability: Uncontrolled Resource Consumption 2. UPDATE INFORMATION This updated advisory is a follow-up to the original advisory titled ICSA-19-283-02 Siemens PROFINET Devices that was published October 10, 2019, on the ICS webpage on us-cert.gov. 3. RISK EVALUATION Successful exploitation of this vulnerability could cause a denial-of-service condition. 4. TECHNICAL DETAILS 4.1 AFFECTED PRODUCTS Siemens reports the vulnerability affects the following PROFINET devices: Siemens reports the vulnerability affects the following PROFINET devices: o Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller: All versions EK-ERTEC 200: All versions EK-ERTEC 200P: All versions o SIMATIC CFU PA: All versions prior to 1.2.0 o SIMATIC ET 200ecoPN (except 6ES7148-6JD00-0AB0 and 6ES7146-6FF00-0AB0): All versions o SIMATIC PROFINET Driver: All versions prior to 2.1 - --------- Begin Update B Part 1 of 2 --------- o SIMATIC ET 200AL (incl. SIPLUS variants): All versions o SIMATIC ET 200M (incl. SIPLUS variants): All versions o SIMATIC ET 200MP IM 155-5 PN BA (incl. SIPLUS variants): All versions prior to 4.2.3 o SIMATIC ET 200MP IM 155-5 PN HF (incl. SIPLUS variants): All versions o SIMATIC ET 200MP IM 155-5 PN ST (incl. SIPLUS variants): All versions o SIMATIC ET 200S (incl. SIPLUS variants): All versions o SIMATIC ET 200SP IM 155-6 PN BA (incl. SIPLUS variants): All versions o SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants): All versions o SIMATIC ET 200SP IM 155-6 PN HF (incl. SIPLUS variants): All versions prior to 4.2.2 o SIMATIC ET 200SP IM 155-6 PN HS (incl. SIPLUS variants): All versions o SIMATIC ET 200SP IM 155-6 PN ST (incl. SIPLUS variants): All versions o SIMATIC ET 200SP IM 155-6 PN/2 HF (incl. SIPLUS variants): All versions prior to 4.2.2 o SIMATIC ET 200SP IM 155-6 PN/3 HF (incl. SIPLUS variants): All versions prior to 4.2.1 o SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants): All versions prior to 2.0 o SIMATIC ET 200pro (incl. SIPLUS variants): All versions o SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants): All versions o SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants): All versions o SIMATIC HMI KTP Mobile Panels (incl. SIPLUS variants): All versions o SIMATIC PN/PN Coupler (incl. SIPLUS NET variants): All versions o SIMATIC S7-1200 CPU family (incl. SIPLUS variants): All versions prior to 4.4.0 o SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants): All versions prior to 2.0 o SIMATIC S7-1500 CPU Software Controller: All versions prior to 2.0 o SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants): All versions o SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants): All versions o SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants): All versions o SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants): All versions prior to 6.0.9 o SIMATIC S7-410 V8 CPU Family (incl. SIPLUS variants): All versions o SINAMICS G110M v4.7 PN Control Unit (incl. SIPLUS variants): All versions prior to 4.7 SP10 HF5 o SINAMICS G120 v4.7 PN Control Unit (incl. SIPLUS variants): All versions prior to 4.7 SP10 HF5 o SINAMICS G130 v4.7 Control Unit: All versions prior to 4.8 o SINAMICS G150 Control Unit: All versions prior to 4.8 o SINAMICS S120 v4.7 Control Unit (incl. SIPLUS variants): All versions o SINAMICS S150 Control Unit: All versions prior to 4.8 - --------- End Update B Part 1 of 2 --------- o SIMATIC WinAC RTX (F) 2010: All versions prior to SP3 o SINAMICS DCM: All versions prior to 1.5 HF1 o SINAMICS DCP: All versions o SINAMICS GH150 v4.7 Control Unit: All versions o SINAMICS GL150 v4.7 Control Unit: All versions o SINAMICS GM150 v4.7 Control Unit: All versions o SINAMICS S110 Control Unit: All versions o SINAMICS SL150 v4.7 Control Unit: All versions prior to 4.7 HF33 o SINAMICS SM120 v4.7 Control Unit: All versions o SINUMERIK 828D: All versions prior to 4.8 SP5 o SINUMERIK 840D sl: All versions 4.2 VULNERABILITY OVERVIEW 4.2.1 UNCONTROLLED RESOURCE CONSUMPTION CWE-400 An unauthenticated attacker sending a large amount of specially crafted UDP packets may trigger a denial-of-service condition. CVE-2019-10936 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is ( AV:N/AC:L/PR:N/UI:N/S:U/C:N/ I:N/A:H ). 4.3 BACKGROUND o CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing o COUNTRIES/AREAS DEPLOYED: Worldwide o COMPANY HEADQUARTERS LOCATION: Germany 4.4 RESEARCHER Siemens reported this vulnerability to CISA. 5. MITIGATIONS o SIMATIC CFU PA: Update to v1.2.0 o SIMATIC PROFINET Driver: Update to v2.1 - --------- Begin Update B Part 2 of 2 --------- o SIMATIC ET 200MP IM 155-5 PN BA (incl. SIPLUS variants): Update to v4.2.3 o SIMATIC ET 200SP IM 155-6 PN HF (incl. SIPLUS variants): Update to v4.2.2 o SIMATIC ET 200SP IM 155-6 PN/2 HF (incl. SIPLUS variants): Update to v4.2.2 o SIMATIC ET 200SP IM 155-6 PN/3 HF (incl. SIPLUS variants): Update to v4.2.1 o SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants): Update to latest version o SIMATIC S7-1200 CPU family (incl. SIPLUS variants): Update to v4.4.0 o SIMATIC S7-1500 Software Controller: Update to the latest version o SIMATIC S7-400H v6 CPU Family (incl. SIPLUS variants): Update to v6.0.9 o SINAMICS G110M v4.7 PN Control Unit (incl. SIPLUS variants): Update to v4.7 SP10 HF5 o SINAMICS G120 v4.7 PN Control Unit (incl. SIPLUS variants): Update to v4.7 SP10 HF5 o SINAMICS G130 v4.7 Control Unit: Update to v5.2 HF1 o SINAMICS G150 Control Unit: Update to v5.2 HF1 o SINAMICS S120 v4.7 Control Unit (incl. SIPLUS variants): Update to v5.2 HF4 o SINAMICS S150 Control Unit: Update to v5.2 HF1 - --------- End Update B Part 2 of 2 --------- o SIMATIC WinAC RTX (F) 2010: Update to SP3 and apply BIOS and Microsoft Windows updates o SINAMICS DCM: Update to v1.5 HF1 o SINAMICS GH150 v4.7 Control Unit: Upgrade to v4.8 SP2 HF9: The update can be obtained from your Siemens representative or via Siemens customer service. o SINAMICS GL150 v4.7 Control Unit: Upgrade to v4.8 SP2 HF9: The update can be obtained from your Siemens representative or via Siemens customer service. o SINAMICS GM150 v4.7 Control Unit: Upgrade to v4.8 SP2 HF9: The update can be obtained from your Siemens representative or via Siemens customer service. o SINAMICS SL150 v4.7 Control Unit: Update to v4.7 HF33 The update can be obtained from your Siemens representative or via Siemens customer service. o SINUMERIK 828D: Update to v4.8 SP5 The update can be obtained from your Siemens representative or via Siemens customer service. Siemens has identified the following specific workarounds and mitigations users can apply to reduce the risk: o Restrict network access to affected devices. As a general security measure, Siemens strongly recommends users protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends users configure the environment according to the Siemens operational guidelines for industrial security , and follow the recommendations in the product manuals. Additional information on industrial security by Siemens can be found at: https://www.siemens.com/industrialsecurity For more information, please see Siemens Security Advisory SSA-473245 CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should: o Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet . o Locate control system networks and remote devices behind firewalls, and isolate them from the business network. o When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on us-cert.gov . Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies . Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies . Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents. No known public exploits specifically target this vulnerability. - --------------------------END INCLUDED TEXT-------------------- You have received this e-mail bulletin as a result of your organisation's registration with AusCERT. The mailing list you are subscribed to is maintained within your organisation, so if you do not wish to continue receiving these bulletins you should contact your local IT manager. If you do not know who that is, please send an email to auscert@auscert.org.au and we will forward your request to the appropriate person. NOTE: Third Party Rights This security bulletin is provided as a service to AusCERT's members. As AusCERT did not write the document quoted above, AusCERT has had no control over its content. The decision to follow or act on information or advice contained in this security bulletin is the responsibility of each user or organisation, and should be considered in accordance with your organisation's site policies and procedures. AusCERT takes no responsibility for consequences which may arise from following or acting on information or advice contained in this security bulletin. NOTE: This is only the original release of the security bulletin. It may not be updated when updates to the original are made. If downloading at a later date, it is recommended that the bulletin is retrieved directly from the author's website to ensure that the information is still current. Contact information for the authors of the original document is included in the Security Bulletin above. If you have any questions or need further information, please contact them directly. Previous advisories and external security bulletins can be retrieved from: https://www.auscert.org.au/bulletins/ =========================================================================== Australian Computer Emergency Response Team The University of Queensland Brisbane Qld 4072 Internet Email: auscert@auscert.org.au Facsimile: (07) 3365 7031 Telephone: (07) 3365 4417 (International: +61 7 3365 4417) AusCERT personnel answer during Queensland business hours which are GMT+10:00 (AEST). On call after hours for member emergencies only. =========================================================================== -----BEGIN PGP SIGNATURE----- Comment: http://www.auscert.org.au/render.html?it=1967 iQIVAwUBXh+vIWaOgq3Tt24GAQhB3BAA2PNY7L5DsAU13C1FZ8OGQh0baWxYZxEa k8uJtEUXZycb1Qfwa2uDVcUtlKvAsFm3tde9VCICvM2JI5oetNpZd1AozGGlYHqJ 9/JymLsUgrAS0FCDKNt6x5RBwaRLVi7QND9yfBJrDESXmE7KQGN4EjoDsy4HpY/z Iz5LqEE6zHr8MrlqbuYCuRN4yN3B5DLOqqjncLB/50QmWTfLO+XUH1rRPp2hVNb5 B8UF6+P2enyeWEfqiVmap1mIdPBRrLDRLfsksBBx1mEu3uC9JsiqYEbrqbBwUZ/1 OwJ/oZYu+XMhg/FOEO5K4Igi9g/AYUJcA/IufkGGxTGghj58SKbdzoWwAt0QQIaz iW3YK1bVLOFgAOi8EesTMAv4Rj8WSKCWobCN5NYxdVIJOtRZaeg1pu6TWhlHxnF5 PfEFTwZ1KscR3PDksj6lDTycH5h0LDmaHUvmPYXBaPUxYPoPTjNClOeQfO/8PciS IWkn2Zn2fZ+xU+WlvAIgUblxUEr2ewAjrW3cP8JDVybDZ27JClyXhqRFim5YR4cJ vO/mj25ivluEK5+6JGDUtnQ3v5QRnjYLrCqVojxW0IfW1bDnDIrghyRZ94q+umAF FDgSYcokJ3PdfS+B9/TsbIDWhq2Vx5NbDc16CBUbMNRW373TWKSh2o3G1Zt2qTCI YMV3Qr2hriE= =2AgG -----END PGP SIGNATURE-----