   Potential CSV injection threat affects IBM Spectrum Control (formerly
            Tivoli Storage Productivity Center) (CVE-2019-4071)
                                9 May 2019

===========================================================================

        AusCERT Security Bulletin Summary
        ---------------------------------

Product:           IBM Spectrum Control Standard Edition
Publisher:         IBM
Operating System:  AIX
                   Linux variants
                   Windows
Impact/Access:     Execute Arbitrary Code/Commands -- Remote with User Interaction
Resolution:        Patch/Upgrade
CVE Names:         CVE-2019-4071  

Original Bulletin: 
   http://www.ibm.com/support/docview.wss?uid=ibm10872900

- --------------------------BEGIN INCLUDED TEXT--------------------

Potential CSV injection threat affects IBM Spectrum Control (formerly Tivoli
Storage Productivity Center) (CVE-2019-4071)

Product:             IBM Spectrum Control Standard Edition
Software version:    5.2.8, 5.2.10.1, 5.2.11, 5.2.12, 5.2.13, 5.2.14, 5.2.15,
                     5.2.15.2, 5.2.16, 5.2.17.0, 5.2.17.1, 5.2.1
Operating system(s): AIX, Linux, Windows
Reference #:         0872900

Security Bulletin

Summary

A potential CSV injection threat can affect IBM Spectrum Control, causing
corrupted data to be inserted in the application.

Vulnerability Details

CVEID: CVE-2019-4071
DESCRIPTION: IBM Tivoli Storage Productivity Center could allow a remote
attacker to execute arbitrary commands on the system, caused by improper
validation of csv file contents.
CVSS Base Score: 6.8
CVSS Temporal Score: See https://exchange.xforce.ibmcloud.com/vulnerabilities/
157063 for the current score
CVSS Environmental Score*: Undefined
CVSS Vector: (CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H)

Affected Products and Versions

+--------------------------------------+-----------------+
|Affected Product                      |Affected Versions|
+--------------------------------------+-----------------+
|IBM Tivoli Storage Productivity Center|5.2.0 - 5.2.7.1  |
+--------------------------------------+-----------------+
|IBM Spectrum Control                  |5.2.8 - 5.2.17.2 |
+--------------------------------------+-----------------+
|IBM Spectrum Control                  |5.3.0 - 5.3.1    |
+--------------------------------------+-----------------+
The versions listed above apply to all licensed offerings of IBM Spectrum
Control.

Remediation/Fixes

The solution is to apply an appropriate IBM Spectrum Control fix. Click on the
download link and follow the Installation Instructions. The solution should be
implemented as soon as practicable.

Starting with 5.2.8, Tivoli Storage Productivity Center has been renamed to IBM
Spectrum Control.

+----------+-----------------+------------------------------------------------------------------------------------+
|Release   |First Fixing     |Link to Fix/Fix Availability Target                                                 |
|          |VRM Level        |                                                                                    |
+----------+-----------------+------------------------------------------------------------------------------------+
|5.2       |5.2.17.3         |http://www.ibm.com/support/docview.wssuid=swg21320822#53_0                         |
+----------+-----------------+------------------------------------------------------------------------------------+
|5.3       |5.3.2            |http://www.ibm.com/support/docview.wssuid=swg21320822#53_0                         |
+----------+-----------------+------------------------------------------------------------------------------------+
Note: It is always recommended to have a current backup before applying any
update procedure.

Workarounds and Mitigations

None.

Change History

7 May 2019 - original version published

                          Cross reference information
     Product       Component  Platform              Version             Edition
  Tivoli Storage             AIX,       5.2.0, 5.2.1, 5.2.2, 5.2.3,
   Productivity              Linux,     5.2.4, 5.2.4.1, 5.2.6, 5.2.7.1
      Center                 Windows

- --------------------------END INCLUDED TEXT--------------------

You have received this e-mail bulletin as a result of your organisation's
registration with AusCERT. The mailing list you are subscribed to is
maintained within your organisation, so if you do not wish to continue
receiving these bulletins you should contact your local IT manager. If
you do not know who that is, please send an email to auscert@auscert.org.au
and we will forward your request to the appropriate person.

NOTE: Third Party Rights
This security bulletin is provided as a service to AusCERT's members.  As
AusCERT did not write the document quoted above, AusCERT has had no control
over its content. The decision to follow or act on information or advice
contained in this security bulletin is the responsibility of each user or
organisation, and should be considered in accordance with your organisation's
site policies and procedures. AusCERT takes no responsibility for consequences
which may arise from following or acting on information or advice contained in
this security bulletin.

NOTE: This is only the original release of the security bulletin.  It may
not be updated when updates to the original are made.  If downloading at
a later date, it is recommended that the bulletin is retrieved directly
from the author's website to ensure that the information is still current.

Contact information for the authors of the original document is included
in the Security Bulletin above.  If you have any questions or need further
information, please contact them directly.

Previous advisories and external security bulletins can be retrieved from:

        https://www.auscert.org.au/bulletins/

===========================================================================
Australian Computer Emergency Response Team
The University of Queensland
Brisbane
Qld 4072

Internet Email: auscert@auscert.org.au
Facsimile:      (07) 3365 7031
Telephone:      (07) 3365 4417 (International: +61 7 3365 4417)
                AusCERT personnel answer during Queensland business hours
                which are GMT+10:00 (AEST).
                On call after hours for member emergencies only.
===========================================================================
-----BEGIN PGP SIGNATURE-----
Comment: http://www.auscert.org.au/render.html?it=1967
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=HEcw
-----END PGP SIGNATURE-----