-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA256 =========================================================================== AUSCERT External Security Bulletin Redistribution ESB-2018.3063 Advisory (ICSA-18-282-04 Siemens SIMATIC S7-1200 CPU Family Version 4 10 October 2018 =========================================================================== AusCERT Security Bulletin Summary --------------------------------- Product: Siemen Simatic S7-1200 Publisher: ICS-CERT Operating System: Network Appliance Impact/Access: Cross-site Request Forgery -- Remote with User Interaction Resolution: Patch/Upgrade CVE Names: CVE-2018-13800 Original Bulletin: https://ics-cert.us-cert.gov/advisories/ICSA-18-282-04 - --------------------------BEGIN INCLUDED TEXT-------------------- Advisory (ICSA-18-282-04) Siemens SIMATIC S7-1200 CPU Family Version 4 Original release date: October 09, 2018 Legal Notice All information products included in http://ics-cert.us-cert.gov are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see http://www.us-cert.gov/tlp/. 1. EXECUTIVE SUMMARY o CVSS v3 7.5 o ATTENTION: Exploitable remotely o Vendor: Siemens o Equipment: SIMATIC S7-1200 CPU Family Version 4 o Vulnerability: Cross-Site Request Forgery (CSRF) 2. RISK EVALUATION Successful exploitation of this vulnerability could allow a CSRF attack if an unsuspecting user is tricked into accessing a malicious link. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports the vulnerability affects the following SIMATIC S7-1200 CPU products: o SIMATIC S7-1200 CPU Family Version 4: All versions prior to 4.2.3 3.2 VULNERABILITY OVERVIEW 3.2.1 CROSS-SITE REQUEST FORGERY (CSRF) CWE-352 The web interface could allow a CSRF attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires interaction with a legitimate user, who must be authenticated to the web interface. A successful attack could allow an attacker to trigger actions via the web interface that the legitimate user is allowed to perform. This could allow the attacker to read or modify parts of the device configuration. CVE-2018-13800 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:R/S:U /C:H/I:H/A:H). 3.3 BACKGROUND o CRITICAL INFRASTRUCTURE SECTORS: Chemical, Energy, Food and Agriculture, Healthcare and Public Health, Transportation Systems, and Water and Wastewater Systems o COUNTRIES/AREAS DEPLOYED: Worldwide o COMPANY HEADQUARTERS LOCATION: Germany 3.4 RESEARCHER Lisa Fournet and Marl Joos from P3 communications GmbH reported this vulnerability to Siemens. 4. MITIGATIONS Siemens provides a firmware update (v4.2.3) and recommends users update to the new version. This update can be found on their website at the following location: https://support.industry.siemens.com/cs/us/en/view/109741461 To reduce the risk, Siemens recommends users not visit other websites while being authenticated against the PLC. As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for industrial security (https:// www.siemens.com/cert/operational-guidelines-industrial-security), and following the recommendations in the product manuals. Additional information on industrial security by Siemens can be found at: https://www.siemens.com/industrialsecurity For more information on this vulnerability and associated software updates, please see Siemens security advisory SSA-507847 on their website: https://www.siemens.com/cert/advisories NCCIC recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should: o Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet. o Locate control system networks and remote devices behind firewalls, and isolate them from the business network. o When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices. NCCIC reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. NCCIC also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. Additional mitigation guidance and recommended practices are publicly available on the ICS-CERT website in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to NCCIC for tracking and correlation against other incidents. NCCIC also recommends that users take the following measures to protect themselves from social engineering attacks: o Do not click web links or open unsolicited attachments in email messages. o Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. o Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. High skill level is needed to exploit. - --------------------------END INCLUDED TEXT-------------------- You have received this e-mail bulletin as a result of your organisation's registration with AusCERT. The mailing list you are subscribed to is maintained within your organisation, so if you do not wish to continue receiving these bulletins you should contact your local IT manager. If you do not know who that is, please send an email to auscert@auscert.org.au and we will forward your request to the appropriate person. NOTE: Third Party Rights This security bulletin is provided as a service to AusCERT's members. As AusCERT did not write the document quoted above, AusCERT has had no control over its content. The decision to follow or act on information or advice contained in this security bulletin is the responsibility of each user or organisation, and should be considered in accordance with your organisation's site policies and procedures. AusCERT takes no responsibility for consequences which may arise from following or acting on information or advice contained in this security bulletin. NOTE: This is only the original release of the security bulletin. It may not be updated when updates to the original are made. If downloading at a later date, it is recommended that the bulletin is retrieved directly from the author's website to ensure that the information is still current. Contact information for the authors of the original document is included in the Security Bulletin above. If you have any questions or need further information, please contact them directly. Previous advisories and external security bulletins can be retrieved from: https://www.auscert.org.au/bulletins/ =========================================================================== Australian Computer Emergency Response Team The University of Queensland Brisbane Qld 4072 Internet Email: auscert@auscert.org.au Facsimile: (07) 3365 7031 Telephone: (07) 3365 4417 (International: +61 7 3365 4417) AusCERT personnel answer during Queensland business hours which are GMT+10:00 (AEST). On call after hours for member emergencies only. =========================================================================== -----BEGIN PGP SIGNATURE----- Comment: http://www.auscert.org.au/render.html?it=1967 iQIVAwUBW72AHWaOgq3Tt24GAQgjlA/+O0kx8m6CHHeUUQB1Wnr0ZXGeY3va37h3 RJ7gDrC0xKUGq5PZdRIi1rjldnjqNLir5cXAXeDe/0ronXW9aqDy9FEb4Io5fT9L ashYyHbN88MK4yBJ0wy8tKsMtubnt5F2hhgchln8Cxp76Fo5FX2o7KKM7ONWJAdj z50UPng678k6U+wnNHnTWyNQvSZOCyGN4YP3YlDKzaULruLY0AfE03netVOWMzJL /379xaaVADVN6lbc6rif1Q/Xg+dkh4PByI7eFAQyYtlLhblpwVKVKuk3WF8TJ/13 zXbMNH4eKHIrnmgZhfchSlel4vcXzyC+Wdu0nf8/wERr5zAVN9FignVifSq7mBO9 ZVTrxxnOwR0zw6LcUKfwedQwqFjMZ43wJJyBEJz4SuJ7A4MqgjJJtwJI7Cm1Uehv CHlOPe91uS9hOF+tX6nZQNio8m6jgU7EbT3pfpE4ahFjsVdkKJsNJppyKWyi9jYb nObAB4lRmcIbt2yWhMqm7a3dUI9eN4MdsqVxeg1jvB5QRLgIVE3bq5vL+pBV6PGM 6X6Nt5VixoxQVTxCe1sSEZE9tkj8GkRh/VXD2BHEi1nUa06ocsg4yCR+w6Ef7GV1 HYg9bz/Lb0cPawIyvAKBoPE6cHGBd/+LTQgRBVUQIUqSZa38A7BcrAPgZ5QNet6P 8Eayd1zk8BE= =u5K0 -----END PGP SIGNATURE-----