Protect yourself against future threats.
-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA256 =========================================================================== AUSCERT External Security Bulletin Redistribution ESB-2018.2635 Opto22 PAC Control Basic and PAC Control Professional 5 September 2018 =========================================================================== AusCERT Security Bulletin Summary --------------------------------- Product: Opto22 PAC Control Basic Opto22 PAC Control Professional Publisher: ICS-CERT Operating System: Network Appliance Impact/Access: Execute Arbitrary Code/Commands -- Remote/Unauthenticated Denial of Service -- Remote/Unauthenticated Resolution: Patch/Upgrade CVE Names: CVE-2018-04154 Original Bulletin: https://ics-cert.us-cert.gov/advisories/ICSA-18-247-01 - --------------------------BEGIN INCLUDED TEXT-------------------- Advisory (ICSA-18-247-01) Opto22 PAC Control Basic and PAC Control Professional Original release date: September 04, 2018 Legal Notice All information products included in http://ics-cert.us-cert.gov are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see http://www.us-cert.gov/tlp/. - ------------------------------------------------------------------------------- 1. EXECUTIVE SUMMARY o CVSS v3 8.4 o ATTENTION: Exploitable remotely/low skill level to exploit o Vendor: Opto22 o Equipment: PAC Control Basic and PAC Control Professional o Vulnerability: Stack-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of this vulnerability could crash the device being accessed, and a buffer overflow condition may then allow remote code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of PAC Control, a control programing software, are affected: o PAC Control Basic Versions R10.0a and prior, and o PAC Control Professional Versions R10.0a and prior. 3.2 VULNERABILITY OVERVIEW 3.2.1 STACK-BASED BUFFER OVERFLOW CWE-121 A stack-based buffer overflow vulnerability may allow remote code execution. CVE-2018-04154 has been assigned to this vulnerability. A CVSS v3 base score of 8.4 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:N/S:U/C:H /I:H/A:H). 3.3 BACKGROUND o CRITICAL INFRASTRUCTURE SECTORS: Multiple o COUNTRIES/AREAS DEPLOYED: Worldwide o COMPANY HEADQUARTERS LOCATION: United States 3.4 RESEARCHER Robert Hawes reported this vulnerability to NCCIC. 4. MITIGATIONS Opto22 recommends users upgrade to the newest version. For more information about this update, please refer to the provided link: https://www.opto22.com/support/resources-tools/knowledgebase/kb87547 NCCIC recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should: o Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet. o Locate control system networks and remote devices behind firewalls, and isolate them from the business network. o When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices. NCCIC reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. NCCIC also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. Additional mitigation guidance and recommended practices are publicly available on the ICS-CERT website in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to NCCIC for tracking and correlation against other incidents. No known public exploits specifically target this vulnerability. - --------------------------END INCLUDED TEXT-------------------- You have received this e-mail bulletin as a result of your organisation's registration with AusCERT. The mailing list you are subscribed to is maintained within your organisation, so if you do not wish to continue receiving these bulletins you should contact your local IT manager. If you do not know who that is, please send an email to auscert@auscert.org.au and we will forward your request to the appropriate person. NOTE: Third Party Rights This security bulletin is provided as a service to AusCERT's members. As AusCERT did not write the document quoted above, AusCERT has had no control over its content. The decision to follow or act on information or advice contained in this security bulletin is the responsibility of each user or organisation, and should be considered in accordance with your organisation's site policies and procedures. AusCERT takes no responsibility for consequences which may arise from following or acting on information or advice contained in this security bulletin. NOTE: This is only the original release of the security bulletin. It may not be updated when updates to the original are made. If downloading at a later date, it is recommended that the bulletin is retrieved directly from the author's website to ensure that the information is still current. Contact information for the authors of the original document is included in the Security Bulletin above. If you have any questions or need further information, please contact them directly. Previous advisories and external security bulletins can be retrieved from: https://www.auscert.org.au/bulletins/ =========================================================================== Australian Computer Emergency Response Team The University of Queensland Brisbane Qld 4072 Internet Email: auscert@auscert.org.au Facsimile: (07) 3365 7031 Telephone: (07) 3365 4417 (International: +61 7 3365 4417) AusCERT personnel answer during Queensland business hours which are GMT+10:00 (AEST). On call after hours for member emergencies only. =========================================================================== -----BEGIN PGP SIGNATURE----- Comment: http://www.auscert.org.au/render.html?it=1967 iQIVAwUBW49xsGaOgq3Tt24GAQiSZhAAmvyv5ABgrZFDTTBXkCNC95hIjF1l2Ich HicmCYGP8uBCq2KJt0wLA3kquGjd/khXhwMRt6Oo+BXINjxzFJizqfaEyt6Z2cyV BZKXBUcVw/fm7WdZhmH/lKhiVkD2ZXj8LXHL9XgrWUwVVf4eT5e03yPpscJkZR/6 GrVczxXeJ4nP6tRzyEhe7ZjJCX8jYx96UwW6PQKzc0VVBsA7ujWb8EeSTp0uOtyF 6CGAdZJnJUIZICeI7z9BrXhiZmuzzu9IeB1VhLiTfGZrYuoHJ3jdj1ELX51Ttpms ylBo+z+fPPlp/qBErznvECj1Mi/1Rvr/1sbs3cvT/PXID/OZJa1Eno2sa9NypsvW Yk3HBUGQoDPtdokT5SX6XOxqZCKzkpdE5vXjEhMujLhJ03EsBkCDFEgPWoSwthfN H8ifN0VGFkwNbFnBVr4Y1PP7XrSMN2xGoLJUkvPAvvvaTm0QwZ3WCpevkInFuUH/ hCtheGfkqnYLs+Z0PbTlu6ONM+rtn9MYhw01qL44InWyzogkQSWs1Bkx4B0aq+Eh Z7aPfyVdXBZQUtvvuZchlpbmXKEFGZ6pABXdDQnk+nuq7V2bxEBAWYUw5ZGFkn/b qCRPSEyAE+y5qfticIBfMzFeAxn1x5SmgU+k+3ZTVmjDkSQTQapkubB0yWOzkI36 vwjTAE2BQCs= =JdyY -----END PGP SIGNATURE-----