-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA256 =========================================================================== AUSCERT External Security Bulletin Redistribution ESB-2018.2552 Advisory (ICSA-18-240-03) 29 August 2018 =========================================================================== AusCERT Security Bulletin Summary --------------------------------- Product: Schneider Electric PowerLogic PM5560 Publisher: ICS-CERT Operating System: Network Appliance Impact/Access: Cross-site Scripting -- Remote with User Interaction Resolution: Patch/Upgrade CVE Names: CVE-2018-7795 Original Bulletin: https://ics-cert.us-cert.gov/advisories/ICSA-18-240-03 - --------------------------BEGIN INCLUDED TEXT-------------------- Advisory (ICSA-18-240-03) Schneider Electric PowerLogic PM5560 Original release date: August 28, 2018 Legal Notice All information products included in http://ics-cert.us-cert.gov are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see http://www.us-cert.gov/tlp/. 1. EXECUTIVE SUMMARY o CVSS v3 8.2 o ATTENTION: Exploitable remotely/low skill level to exploit o Vendor: Schneider Electric o Equipment: PowerLogic PM5560 o Vulnerability: Cross-site Scripting 2. RISK EVALUATION Successful exploitation of this vulnerability could allow user input to be manipulated, allowing for remote code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of PowerLogic PM5560, a power management system, are affected: o PowerLogic PM5560 all versions prior to firmware Version 2.5.4 3.2 VULNERABILITY OVERVIEW 3.2.1 IMPROPER NEUTRALIZATION OF INPUT DURING WEB PAGE GENERATION ('CROSS-SITE SCRIPTING') CWE-79 The PowerLogic PM5560 product is susceptible to cross-site scripting attack on its web browser. An attacker may be able to manipulate inputs to cause execution of java script code. CVE-2018-7795 has been assigned to this vulnerability. A CVSS v3 base score of 8.2 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:L/A:N). 3.3 BACKGROUND o CRITICAL INFRASTRUCTURE SECTORS: Energy o COUNTRIES/AREAS DEPLOYED: Worldwide o COMPANY HEADQUARTERS LOCATION: France 3.4 RESEARCHER Schneider Electric, working with Ezequiel Fernandez and Bertin Jose, reported this vulnerability to NCCIC. 4. MITIGATIONS Schneider Electric has released a fix to address this vulnerability: https://www.schneider-electric.com/en/download/document/PM5560_PM5563_V2.5.4_Release/ For more information please see the Schneider Electric security notification at: https://www.schneider-electric.com/en/download/document/SEVD-2018-228-01/ NCCIC recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should: o Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet. o Locate control system networks and remote devices behind firewalls, and isolate them from the business network. o When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices. NCCIC reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. NCCIC also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. Additional mitigation guidance and recommended practices are publicly available on the ICS-CERT website in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to NCCIC for tracking and correlation against other incidents. No known public exploits specifically target this vulnerability. Contact Information For any questions related to this report, please contact the NCCIC at: Email: NCCICCUSTOMERSERVICE@hq.dhs.gov Toll Free: 1-888-282-0870 For industrial control systems cybersecurity information: http://ics-cert.us-cert.gov or incident reporting: https://ics-cert.us-cert.gov/Report-Incident? The NCCIC continuously strives to improve its products and services. You can help by choosing one of the links below to provide feedback about this product. - --------------------------END INCLUDED TEXT-------------------- You have received this e-mail bulletin as a result of your organisation's registration with AusCERT. The mailing list you are subscribed to is maintained within your organisation, so if you do not wish to continue receiving these bulletins you should contact your local IT manager. If you do not know who that is, please send an email to auscert@auscert.org.au and we will forward your request to the appropriate person. NOTE: Third Party Rights This security bulletin is provided as a service to AusCERT's members. As AusCERT did not write the document quoted above, AusCERT has had no control over its content. The decision to follow or act on information or advice contained in this security bulletin is the responsibility of each user or organisation, and should be considered in accordance with your organisation's site policies and procedures. AusCERT takes no responsibility for consequences which may arise from following or acting on information or advice contained in this security bulletin. NOTE: This is only the original release of the security bulletin. It may not be updated when updates to the original are made. If downloading at a later date, it is recommended that the bulletin is retrieved directly from the author's website to ensure that the information is still current. Contact information for the authors of the original document is included in the Security Bulletin above. If you have any questions or need further information, please contact them directly. Previous advisories and external security bulletins can be retrieved from: https://www.auscert.org.au/bulletins/ =========================================================================== Australian Computer Emergency Response Team The University of Queensland Brisbane Qld 4072 Internet Email: auscert@auscert.org.au Facsimile: (07) 3365 7031 Telephone: (07) 3365 4417 (International: +61 7 3365 4417) AusCERT personnel answer during Queensland business hours which are GMT+10:00 (AEST). On call after hours for member emergencies only. =========================================================================== -----BEGIN PGP SIGNATURE----- Comment: http://www.auscert.org.au/render.html?it=1967 iQIVAwUBW4Y0vWaOgq3Tt24GAQjFHxAAs61kKOSDwPbVstdAwSyUrCzkKMsWSXqx tf1GmMdocjBONbQoJSinu/sLEFNJeKjM3aCRKm9Lst5m1tsQzC+zmHixRUVcWzgT q9KRoZa+HtwJ3Tp5rn1OG3T+yPhNA/MwZiZLR93Qd25VzZ8/1dd1A1iilOJ5Wb2T /XtNqbiaZGjA5Xb6SsnjlK2D4YWjNHULCk8ZCvG8MGzC6JRMwYevf0ZY/XI39C7p FGjb0AxpmsWjFz0XTyVISco550NFNVd7LYbzPm8Rakolh+eWGsww9D1NCx+GmYYc 73ZDcq4dzpQrA64Dg3kl7XzajZYavlN4eFIv+CSpX62+nwDLGaPjZlfmUw/T60Dk vu9Yxz+EFW9SqPJwEzZ4tMixSaYN7UnBvgJ+1pkOLNmBERqBXM+R2Wvsm/ujC8e7 I2j4Qptt6pK6BWBhL6iD2Kb1AcTv6CN8YXhSi2Q5scqEIO9j5uht1mcVqsySSwtD Q65ND6ljVZ53j6xDCs04RRtix5eYEtRo5rksommVLaGol3zNYlVDUUZCJJCeDu8C tFcUAtR4ZjB7mBVl8NMZK/dcAvtEvB+JfaZ/X7ZE7N23ZvKcyNuzvixAtoF6I4gq 0vRQp7ytLHy8W9lEusBkp26Oa/3+y//YMEJ6Ds7GmN5KyysCRXiVSaiyPLjWaB46 z7OLUAJ1KhU= =jCeJ -----END PGP SIGNATURE-----