Protect yourself against future threats.
-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA256 =========================================================================== AUSCERT External Security Bulletin Redistribution ESB-2018.0208.2 Multiple vulnerabilities have been identified in Siemens SIMATIC WinCC Add-On 28 February 2018 =========================================================================== AusCERT Security Bulletin Summary --------------------------------- Product: Siemens SIMATIC WinCC Publisher: ICS-CERT Operating System: Windows Impact/Access: Execute Arbitrary Code/Commands -- Remote/Unauthenticated Denial of Service -- Remote/Unauthenticated Access Confidential Data -- Remote/Unauthenticated Reduced Security -- Remote/Unauthenticated Resolution: Patch/Upgrade CVE Names: CVE-2017-12822 CVE-2017-12821 CVE-2017-12820 CVE-2017-12819 CVE-2017-12818 CVE-2017-11498 CVE-2017-11497 CVE-2017-11496 Original Bulletin: https://ics-cert.us-cert.gov/advisories/ICSA-18-018-01A Revision History: February 28 2018: Bulletin updated with additional CVEs January 19 2018: Initial Release - --------------------------BEGIN INCLUDED TEXT-------------------- Advisory (ICSA-18-018-01A) Siemens SIMATIC WinCC Add-On (Update A) Original release date: January 18, 2018 | Last revised: February 27, 2018 Legal Notice All information products included in http://ics-cert.us-cert.gov are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see http://www.us-cert.gov/tlp/. CVSS v3 9.8 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: Siemens Equipment: SIMATIC WinCC Add-On Vulnerabilities: Stack-based Buffer Overflow, Improper Input Validation, Improper Restriction of Operations within the Bounds of a Memory Buffer, Security Features, Improper Access Control. UPDATE INFORMATION This updated advisory is a follow-up to the original advisory titled ICSA-18-018-01 Siemens SIMATIC WinCC Add-On that was published January 18, 2018, on the NCCIC/ICS-CERT website. AFFECTED PRODUCTS Siemens reports that the vulnerabilities affect the following versions of SIMATIC WinCC Add-On: SIMATIC WinCC Add-On Historian CONNECT ALARM all versions prior to and including v5.x, SIMATIC WinCC Add-On PI CONNECT ALARM all versions prior to and including v2.x, SIMATIC WinCC Add-On PI CONNECT AUDIT TRAIL all versions prior to and including v1.x, SIMATIC WinCC Add-On PM-AGENT all versions prior to and including v5.x, SIMATIC WinCC Add-On PM-ANALYZE all versions prior to and including v7.x, SIMATIC WinCC Add-On PM-CONTROL all versions prior to and including v10.x, SIMATIC WinCC Add-On PM-MAINT all versions prior to and including v9.x, SIMATIC WinCC Add-On PM-OPEN EXPORT all versions prior to and including v7.x, SIMATIC WinCC Add-On PM-OPEN HOST-S all versions prior to and including v7.x, SIMATIC WinCC Add-On PM-OPEN IMPORT all versions prior to and including v6.x, SIMATIC WinCC Add-On PM-OPEN PI all versions prior to and including v7.x, SIMATIC WinCC Add-On PM-OPEN PV02 all versions prior to and including v1.x, SIMATIC WinCC Add-On PM-OPEN TCP/IP all versions prior to and including v8.x, SIMATIC WinCC Add-On PM-QUALITY all versions prior to and including v9.x, SIMATIC WinCC Add-On SICEMENT IT MIS all versions prior to and including v7.x, and SIMATIC WinCC Add-On SIPAPER IT MIS all versions prior to and including v7.x IMPACT Successful exploitation of these vulnerabilities could allow remote code execution or a denial of service condition. MITIGATION Gemalto has released an updated installer and Siemens strongly encourages users upgrade to the new installer as soon as possible. The new installer is available at: https://supportportal.gemalto.com/csm/?id=kb_article&sys_id=a459d328dba207c8fe0aff3dbf9619ce (link is external) Siemens also advises that users configure the operational environment according to Siemens' Operational Guidelines for Industrial Security: https://www.siemens.com/cert/operational-guidelines-industrial-security (link is external) For more information on these vulnerabilities and more detailed mitigation instructions, please see Siemens Security Advisory SSA-127490 at the following location: http://www.siemens.com/cert/advisories (link is external) NCCIC recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should: Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls, and isolate them from the business network. When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices. NCCIC reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. NCCIC also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. Additional mitigation guidance and recommended practices are publicly available in the NCCIC Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies, that is available for download from the ICS-CERT website. Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to NCCIC for tracking and correlation against other incidents. No known public exploits specifically target these vulnerabilities. VULNERABILITY OVERVIEW STACK-BASED BUFFER OVERFLOW CWE-121 Malformed ASN1 streams in V2C and similar input files can be used to generate stack-based buffer overflows. The vulnerability could allow arbitrary code execution. CVE-2017-11496 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). STACK-BASED BUFFER OVERFLOW CWE-121 Language packs containing malformed filenames could lead to a stack-based buffer overflow. The vulnerability could allow arbitrary code execution. CVE-2017-11497 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). IMPROPER INPUT VALIDATION CWE-20 Language pack (ZIP file) with invalid HTML files could lead to NULL pointer access. The vulnerability could cause denial of service of the remote process. CVE-2017-11498 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). - --------- Begin Update A Part 1 of 1 -------- IMPROPER RESTRICTION OF OPERATIONS WITHIN THE BOUNDS OF A MEMORY BUFFER CWE-119 A stack overflow flaw in the custom XML parser could allow remote denial of service. CVE-2017-12818 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). SECURITY FEATURES CWE-254 Remote manipulation of the language pack updater could allow NTLM relay attacks. CVE-2017-12819 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). IMPROPER RESTRICTION OF OPERATIONS WITHIN THE BOUNDS OF A MEMORY BUFFER CWE-119 Arbitrary memory read from controlled memory pointer could allow remote denial of service. CVE-2017-12820 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). IMPROPER RESTRICTION OF OPERATIONS WITHIN THE BOUNDS OF A MEMORY BUFFER CWE-119 A memory corruption flaw could allow remote code execution. CVE-2017-12821 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). IMPROPER ACCESS CONTROL CWE-284 The administrative interface can be remotely enabled and disabled without authentication. This could increase the attack surface. CVE-2017-12822 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N). - --------- End Update A Part 1 of 1 ---------- RESEARCHER Sergey Temnikov and Vladimir Dashchenko from Kaspersky Lab reported these vulnerabilities to Siemens. BACKGROUND Critical Infrastructure Sectors: Chemical, Energy, Food and Agriculture, Water and Wastewater Systems. Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Contact Information For any questions related to this report, please contact the NCCIC at: Email: NCCICCUSTOMERSERVICE@hq.dhs.gov (link sends e-mail) Toll Free: 1-888-282-0870 For industrial control systems cybersecurity information: http://ics-cert.us-cert.gov or incident reporting: https://ics-cert.us-cert.gov/Report-Incident? - --------------------------END INCLUDED TEXT-------------------- You have received this e-mail bulletin as a result of your organisation's registration with AusCERT. The mailing list you are subscribed to is maintained within your organisation, so if you do not wish to continue receiving these bulletins you should contact your local IT manager. If you do not know who that is, please send an email to auscert@auscert.org.au and we will forward your request to the appropriate person. NOTE: Third Party Rights This security bulletin is provided as a service to AusCERT's members. As AusCERT did not write the document quoted above, AusCERT has had no control over its content. The decision to follow or act on information or advice contained in this security bulletin is the responsibility of each user or organisation, and should be considered in accordance with your organisation's site policies and procedures. AusCERT takes no responsibility for consequences which may arise from following or acting on information or advice contained in this security bulletin. NOTE: This is only the original release of the security bulletin. It may not be updated when updates to the original are made. If downloading at a later date, it is recommended that the bulletin is retrieved directly from the author's website to ensure that the information is still current. Contact information for the authors of the original document is included in the Security Bulletin above. If you have any questions or need further information, please contact them directly. Previous advisories and external security bulletins can be retrieved from: https://www.auscert.org.au/bulletins/ =========================================================================== Australian Computer Emergency Response Team The University of Queensland Brisbane Qld 4072 Internet Email: auscert@auscert.org.au Facsimile: (07) 3365 7031 Telephone: (07) 3365 4417 (International: +61 7 3365 4417) AusCERT personnel answer during Queensland business hours which are GMT+10:00 (AEST). On call after hours for member emergencies only. =========================================================================== -----BEGIN PGP SIGNATURE----- Comment: http://www.auscert.org.au/render.html?it=1967 iQIVAwUBWpY4Z4x+lLeg9Ub1AQjvcA/+M4Mk7qsuquYusP3a7fDxQX5T7PP2t/uj JW5F0GjGx/Qi+ZpnL8rubmQe9asH61ZwqLhhonYpw/NbCelrf8EWV/iZiVmfmrKf ZM6ZeTpIaxOrw9QcGs43L4URTD33B7By2U7Sos+sMV+EnkrpE483TgnlMGTckoDX SE5UgmnkIbSIVoWzf3h4+kXrHU9WDo2lOr2lEaAvHHwqjNcturpd+EqtAdAkPy/p +ADIGaGAQjB39EsN6HhY5NtQ/Z/SC2SADTkwAyNMyaIKKLwdPNhrQoYQiYY+SibI +oJcp9CDsbeAteLQISK/kcshs5wIj+pQWqUr8jt7jE9k4CyWds8L3sbVZeCj38NP uO69nGFDFmVwvR2fCQClJu3OCutn8d4zNH2Ev0NHCH787uCEIAbtx0Ih2qv7BSts j4jf6ry5PdqXtPnjofuUMuDj5VZBuanb5olMeJB6GEj08Q6fgfkQKpv+plWSNw/W cuzTv/6kaKs61/diO0ZzXPIWbbt4oDqR8k5jQ0qMFD28DgxN2b+etqxR7C+ry6ch OWo2FvfJBn6WoSvbouuz7NtmEDPnEyMa9wjmcvX5u1grrZ05DcOO2sbcqXDkvp/B h+yljI+mmvRT47izjQw8XLf2C71nKJKcznRssl475PJvc3mgfiFH4ffnDZEjIBFR /30q7GfoRI0= =u3mE -----END PGP SIGNATURE-----