Protect yourself against future threats.
-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA256 =========================================================================== AUSCERT External Security Bulletin Redistribution ESB-2023.4752 ICS Advisory | ICSA-23-229-03 Schneider Electric PowerLogic ION7400 / PM8000 / ION8650 / ION8800 / ION9000 Power Meters 18 August 2023 =========================================================================== AusCERT Security Bulletin Summary --------------------------------- Product: Schneider Electric PowerLogic ION7400 / PM8000 / ION8650 / ION8800 / ION9000 Power Meters Publisher: ICS-CERT Operating System: Network Appliance Resolution: Patch/Upgrade CVE Names: CVE-2022-46680 Original Bulletin: https://www.cisa.gov/news-events/ics-advisories/icsa-23-229-03 Comment: CVSS (Max): 8.8 CVE-2022-46680 (CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H) CVSS Source: ICS-CERT Calculator: https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H - --------------------------BEGIN INCLUDED TEXT-------------------- ICS Advisory (ICSA-23-229-03) Schneider Electric PowerLogic ION7400 / PM8000 / ION8650 / ION8800 / ION9000 Power Meters Release Date August 17, 2023 1. EXECUTIVE SUMMARY o CVSS v3 8.8 o ATTENTION: Exploitable remotely/low attack complexity o Vendor: Schneider Electric o Equipment: PowerLogic ION7400 / PM8000 / ION8650 / ION8800 / ION9000 o Vulnerability: Cleartext Transmission of Sensitive Information 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to cause a disclosure of sensitive information, a denial of service, or modification of data if an attacker is able to intercept network traffic. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following components of Schneider Electric PowerLogic, a power meter, are affected: o PowerLogic ION9000: All versions prior to 4.0.0 o PowerLogic ION7400: All versions prior to 4.0.0 o PowerLogic PM8000: All versions prior to 4.0.0 o PowerLogic ION8650: All versions o PowerLogic ION8800: All versions o Legacy ION products: All versions 3.2 VULNERABILITY OVERVIEW 3.2.1 CLEARTEXT TRANSMISSION OF SENSITIVE INFORMATION CWE-319 A cleartext transmission of sensitive information vulnerability exists that could cause disclosure of sensitive information, denial of service, or modification of data if an attacker is able to intercept network traffic. CVE-2022-46680 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is ( AV:N/AC:L/PR:N/UI:R/S:U/ C:H/I:H/A:H ). 3.3 BACKGROUND o CRITICAL INFRASTRUCTURE SECTORS: Commercial Facilities, Critical Manufacturing, Energy o COUNTRIES/AREAS DEPLOYED: Worldwide o COMPANY HEADQUARTERS LOCATION: France 3.4 RESEARCHER Jos Wetzels of Forescout Technologies reported these vulnerabilities to Schneider Electric. 4. MITIGATIONS Schneider Electric has released the following remediations for users to implement: o Update affected components to current firmware versions for available vulnerability fixes: ? PowerLogic ION9000: Version 4.0.0 is available for download. ? PowerLogic ION7400: Version 4.0.0 is available for download. ? PowerLogic PM8000: Version 4.0.0 is available for download. o Users should use appropriate patching methodologies when applying these patches to their systems. Schneider Electric recommends using backups and evaluating the impact of these patches in a "testing and development environment" or on an offline infrastructure. o Users should contact Schneider Electric for assistance in removing a patch. o Schneider Electric recommends that users ensure devices supporting ION protocol are not exposed to the internet or other untrusted networks. Users should apply the best practices for network hardening as documented in the product user guide and the Schneider Electric Recommended Cybersecurity Best Practices . o Additional configuration steps and supporting software are required to utilize the secure ION feature. Please refer to the relevant product documentation or contact customer care for additional details and support. For more information, see Schneider Electric's security advisory SEVD-2023-129-03 . Schneider Electric strongly recommends the following industry cybersecurity best practices: o Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. o Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. o Place all controllers in locked cabinets and never leave them in the "Program" mode. o Never connect programming software to any network other than the network intended for that device. o Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. o Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. o Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the internet. o When remote access is required, use secure methods, such as virtual private networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage at cisa.gov/ics . Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies . Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies . Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploits specifically targeting these vulnerabilities have been reported to CISA at this time. This product is provided subject to this Notification and this Privacy & Use policy. Vendor Schneider Electric - --------------------------END INCLUDED TEXT-------------------- You have received this e-mail bulletin as a result of your organisation's registration with AusCERT. The mailing list you are subscribed to is maintained within your organisation, so if you do not wish to continue receiving these bulletins you should contact your local IT manager. If you do not know who that is, please send an email to auscert@auscert.org.au and we will forward your request to the appropriate person. NOTE: Third Party Rights This security bulletin is provided as a service to AusCERT's members. As AusCERT did not write the document quoted above, AusCERT has had no control over its content. The decision to follow or act on information or advice contained in this security bulletin is the responsibility of each user or organisation, and should be considered in accordance with your organisation's site policies and procedures. AusCERT takes no responsibility for consequences which may arise from following or acting on information or advice contained in this security bulletin. NOTE: This is only the original release of the security bulletin. It may not be updated when updates to the original are made. If downloading at a later date, it is recommended that the bulletin is retrieved directly from the author's website to ensure that the information is still current. Contact information for the authors of the original document is included in the Security Bulletin above. If you have any questions or need further information, please contact them directly. Previous advisories and external security bulletins can be retrieved from: https://www.auscert.org.au/bulletins/ =========================================================================== Australian Computer Emergency Response Team The University of Queensland Brisbane Qld 4072 Internet Email: auscert@auscert.org.au Facsimile: (07) 3365 7031 Telephone: (07) 3365 4417 (International: +61 7 3365 4417) AusCERT personnel answer during Queensland business hours which are GMT+10:00 (AEST). On call after hours for member emergencies only. =========================================================================== -----BEGIN PGP SIGNATURE----- Comment: https://auscert.org.au/gpg-key/ iQIVAwUBZN7C48kNZI30y1K9AQhMlRAAqdWH7VeN42xisClziNpk/qpeWwq58N8s pDOQtYMe81fZ/Q2CExfKiDKDixC1W6syL2RVOZQgPppVo9nAxluIMXFQd4bFllqM QDsMJL399X+D1moDzOfiFCuXE5/82hbl1iHWvrL/j+65POPzbNdv2sJxNEDpwZok fS5mHDDAlAlDSPktktQaq0vkArj91rkr1OSH6FdC2xysxRNilsM68TqFsrwwUx67 5BSNDPO4OiceMaIDnTtOxlNHtZ/y5cHjk3H8eWgQanAT91bKDy1HiiW0tOv6wdKl WjzIE08bYhUz8t77klZp5AXokDN8Wrsz7u+/a0v/8zErI/TrnaJUfEVv2iNyZBbL gZkmixD0odnbmURxIdKf+KrH8AQZlbCz7p19QxVLgwLne+tP1xbQSN2XHZlHlALx FfXtpeGNahh1dWpY8SdjDtfFd+s74Vkc5N38oFVwHF+fAgTSpVcTy4u8jA5aITHH CF4lySWda3Ays7xHJ7Xdc7JuNQWRVw+XZ525P8ZaTdnQJOXAFEzizfYhEvAsdJ3/ oldEF4bv9EnDw99WDvkM/MCTDcxGz8myN2cH/I5vCHBcpkj5VjuiUJmsnlj6qoI7 pvnJHZdzfYy+j3Tho1YBI6N0cOQ4hks6VYmfE2lHTfZ+xEczTNGFZryU9hmiaJ+x coIOBme0niQ= =YRrE -----END PGP SIGNATURE-----