-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA256 =========================================================================== AUSCERT External Security Bulletin Redistribution ESB-2022.6572 Advisory (icsa-22-346-05) Siemens PLM Help Server 16 December 2022 =========================================================================== AusCERT Security Bulletin Summary --------------------------------- Product: Siemens PLM Help Server Publisher: ICS-CERT Operating System: Network Appliance Resolution: Alternate Program CVE Names: CVE-2022-44575 Original Bulletin: https://us-cert.cisa.gov/ics/advisories/icsa-22-346-05 Comment: CVSS (Max): 6.1 CVE-2022-44575 (CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N) CVSS Source: ICS-CERT Calculator: https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N - --------------------------BEGIN INCLUDED TEXT-------------------- ICS Advisory (ICSA-22-346-05) Siemens PLM Help Server Original release date: December 15, 2022 Legal Notice All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/ . 1. EXECUTIVE SUMMARY o CVSS v3 6.1 o ATTENTION: Exploitable remotely/low attack complexity o Vendor: Siemens o Equipment: PLM Help Server o Vulnerability: Cross-site Scripting 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to execute code after tricking users into accessing malicious links. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Siemens PLM Help Server, a documentation server, are affected: o Version 4.2 3.2 VULNERABILITY OVERVIEW 3.2.1 IMPROPER NEUTRALIZATION OF INPUT DURING WEB PAGE GENERATION ('CROSS-SITE SCRIPTING') CWE-79 A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected application that could allow an attacker to execute malicious javascript code by tricking users into accessing a malicious link. CVE-2022-44575 has been assigned to this vulnerability. A CVSS v3 base score of 6.1 has been calculated; the CVSS vector string is ( AV:N/AC:L/PR:N/UI:R/S:C/ C:L/I:L/A:N ). 3.3 BACKGROUND o CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing o COUNTRIES/AREAS DEPLOYED: Worldwide o COMPANY HEADQUARTERS LOCATION: Germany 3.4 RESEARCHER Michael Heinzl reported this vulnerability to Siemens. 4. MITIGATIONS This product has reached end-of-life, and security vulnerabilities are no longer patched. Siemens released a new version of Documentation Server, which fixes this vulnerability. Siemens recommends upgrading to Siemens Documentation Server V2.1 or later versions. Once the new Documentation Server is installed, users should download and install the documentation packages. Information on installation is included in the install guides. Refer to PL8681100 (login required) for additional information. Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk: Do not open unknown links while working on PLM Help Server V4.2 As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for industrial security and to follow the recommendations in the product manuals. For more information, see Siemens security advisory SSA-274282 in HTML or CSAF . CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should: o Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet . o Locate control system networks and remote devices behind firewalls and isolate them from the business network. o When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov . Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies . Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies . Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: o Do not click web links or open attachments in unsolicited email messages. o Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. o Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploits specifically target this vulnerability. For any questions related to this report, please contact the CISA at: Email: CISAservicedesk@cisa.dhs.gov Toll Free: 1-888-282-0870 - --------------------------END INCLUDED TEXT-------------------- You have received this e-mail bulletin as a result of your organisation's registration with AusCERT. The mailing list you are subscribed to is maintained within your organisation, so if you do not wish to continue receiving these bulletins you should contact your local IT manager. If you do not know who that is, please send an email to auscert@auscert.org.au and we will forward your request to the appropriate person. NOTE: Third Party Rights This security bulletin is provided as a service to AusCERT's members. As AusCERT did not write the document quoted above, AusCERT has had no control over its content. The decision to follow or act on information or advice contained in this security bulletin is the responsibility of each user or organisation, and should be considered in accordance with your organisation's site policies and procedures. AusCERT takes no responsibility for consequences which may arise from following or acting on information or advice contained in this security bulletin. NOTE: This is only the original release of the security bulletin. It may not be updated when updates to the original are made. If downloading at a later date, it is recommended that the bulletin is retrieved directly from the author's website to ensure that the information is still current. Contact information for the authors of the original document is included in the Security Bulletin above. If you have any questions or need further information, please contact them directly. Previous advisories and external security bulletins can be retrieved from: https://www.auscert.org.au/bulletins/ =========================================================================== Australian Computer Emergency Response Team The University of Queensland Brisbane Qld 4072 Internet Email: auscert@auscert.org.au Facsimile: (07) 3365 7031 Telephone: (07) 3365 4417 (International: +61 7 3365 4417) AusCERT personnel answer during Queensland business hours which are GMT+10:00 (AEST). On call after hours for member emergencies only. =========================================================================== -----BEGIN PGP SIGNATURE----- Comment: https://auscert.org.au/gpg-key/ iQIVAwUBY5vEgskNZI30y1K9AQiTthAArrVcWHRHciy9QdhZgLdgjqdXLoMtJwOp wPE9cyXvcUqqSsx5YXKshrQkjbm+XIkZBeZeYdXgMxNZukWtRFF1cdOLZvXIoSb5 z/qcx12YB7yCxZFglnsZCkZoDcGN2BqbW45/V6nvu3aM3F7POpB41OcYfaFw+mDB GOIpH6xE32I2QlSn+Rb7vKObgZl+Um9Rb8Iw+MyMQ3yh9+mT3t2JfLZzM2jK38pP eopGKcIRG3PY4fCUaYEHzenqZwDBdIH39xhbMKaNwgr08J/u1/GgneHy+iDO7Hw6 TzN6W4GSGekSdb5eDffS8PO55Kc2fT4YhcA8aCg1V+cRmhylM+SWMvJXRxz+NYkL xWx/YDX1TOmz0YRh8DaO+kJKFeYAdI/g9hAuSz0WIK0L/NHgOUA49GAfdjcbQ9GB zWBVAw3CIh6BrdPYxHnB9X7Kolf2dqxl3XZlbDrFC/q/qoc7V+46prb02dCUVJr4 Ew6tsqsRJOl0ap4XPmaWGR4tQ1UIPnInVjvJ9V4gpiBP2MSlQfSBgWQJuF2SDzH0 e/mi2khty1tqJtPvB8reewQHUHAAAu4N3upEJZcdwUZ/rFQpqtI+REVcAI2m0NUh iRT9fT3xyEQYf8+ONtUgsVhaYHxGpZBpSAhswK0mTF3zjxtsSSkX5PyFOWx104wA e7ZtG6RZir8= =f/8G -----END PGP SIGNATURE-----