Protect yourself against future threats.
-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA256 =========================================================================== AUSCERT External Security Bulletin Redistribution ESB-2022.5374.2 Advisory (icsa-22-298-07) Delta Electronics InfraSuite Device Master 12 January 2023 =========================================================================== AusCERT Security Bulletin Summary --------------------------------- Product: Delta Electronics InfraSuite Device Master Publisher: ICS-CERT Operating System: Network Appliance Resolution: Patch/Upgrade CVE Names: CVE-2022-41779 CVE-2022-41778 CVE-2022-41776 CVE-2022-41772 CVE-2022-41688 CVE-2022-41657 CVE-2022-41644 CVE-2022-41629 CVE-2022-40202 CVE-2022-38142 Original Bulletin: https://us-cert.cisa.gov/ics/advisories/icsa-22-298-07 Revision History: January 12 2023: Vendor Update October 26 2022: Initial Release - --------------------------BEGIN INCLUDED TEXT-------------------- ICS Advisory (ICSA-22-298-07) Delta Electronics InfraSuite Device Master (Update A) Original release date: January 10, 2023 | Last revised: January 11, 2023 Legal Notice All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/ . 1. EXECUTIVE SUMMARY o CVSS v3 9.8 o ATTENTION: Exploitable remotely/low attack complexity o Vendor: Delta Electronics o Equipment: InfraSuite Device Master o Vulnerabilities: Deserialization of Untrusted Data, Path Traversal, Missing Authentication for Critical Function 2. UPDATE OR REPOSTED INFORMATION This updated advisory is a follow-up to the original advisory titled ICSA-22-298-07 Delta Electronics InfraSuite Device Master that was published October 25, 2022, on the ICS webpage on cisa.gov/ICS. 3. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an unauthenticated attacker to remotely execute code, cause a denial-of-service condition by remotely deleting files or changing group privileges, or remotely read and write files, all with local administrator privileges. 4. TECHNICAL DETAILS 4.1 AFFECTED PRODUCTS The following versions of InfraSuite Device Master, a real-time device monitoring software, are affected: o Version 00.00.01a and prior - --------- Begin Update A part 1 of 2 --------- o InfraSuite Device Master: Versions prior to 1.0.3 (CVE-2022-41657 and CVE-2022-40202 only) - --------- End Update A part 1 of 2 --------- 4.2 VULNERABILITY OVERVIEW 4.2.1 DESERIALIZATION OF UNTRUSTED DATA CWE-502 Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-DataCollect service port without proper verification. An attacker could provide malicious serialized objects to execute arbitrary code upon deserialization. CVE-2022-41778 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is ( AV:N/AC:L/PR:N/UI:N/S:U/ C:H/I:H/A:H ). 4.2.2 DESERIALIZATION OF UNTRUSTED DATA CWE-502 Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-Gateway service port without proper verification. An attacker could provide malicious serialized objects to execute arbitrary code upon deserialization. CVE-2022-38142 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is ( AV:N/AC:L/PR:N/UI:N/S:U/ C:H/I:H/A:H ). 4.2.3 DESERIALIZATION OF UNTRUSTED DATA CWE-502 Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize network packets without proper verification. If the device connects to an attacker-controlled server, the attacker could send maliciously crafted packets that would be deserialized and executed, leading to remote code execution. CVE-2022-41779 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is ( AV:N/AC:L/PR:N/UI:R/S:U/ C:H/I:H/A:H ). 4.2.4 IMPROPER LIMITATION OF A PATHNAME TO A RESTRICTED DIRECTORY ('PATH TRAVERSAL') CWE-22 Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior allow attacker provided data already serialized into memory to be used in file operation application programmable interfaces (APIs). This could create arbitrary files, which could be used in API operations and could ultimately result in remote code execution. CVE-2022-41657 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is ( AV:N/AC:L/PR:N/UI:N/S:U/ C:H/I:H/A:H ). 4.2.5 IMPROPER LIMITATION OF A PATHNAME TO A RESTRICTED DIRECTORY ('PATH TRAVERSAL') CWE-22 Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior mishandle .ZIP archives containing characters used in path traversal. This path traversal could result in remote code execution. CVE-2022-41772 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is ( AV:N/AC:L/PR:N/UI:N/S:U/ C:H/I:H/A:H ). 4.2.6 MISSING AUTHENTICATION FOR CRITICAL FUNCTION CWE-306 The database backup function in Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior lacks proper authentication. An attacker could provide malicious serialized objects which, when deserialized, could activate an opcode for a backup scheduling function without authentication. This function allows the user to designate all function arguments and the file to be executed. This could allow the attacker to start any new process and achieve remote code execution. CVE-2022-40202 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is ( AV:N/AC:L/PR:N/UI:N/S:U/ C:H/I:H/A:H ). 4.2.7 MISSING AUTHENTICATION FOR CRITICAL FUNCTION CWE-306 Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lack proper authentication for functions that create and modify user groups. An attacker could provide malicious serialized objects that could run these functions without authentication to create a new user and add them to the administrator group. CVE-2022-41688 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is ( AV:N/AC:L/PR:N/UI:N/S:U/ C:H/I:H/A:H ). 4.2.8 MISSING AUTHENTICATION FOR CRITICAL FUNCTION CWE-306 Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lacks authentication for a function that changes group privileges. An attacker could use this to create a denial-of-service state or escalate their own privileges. CVE-2022-41644 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is ( AV:N/AC:L/PR:L/UI:N/S:U/ C:H/I:H/A:H ). 4.2.9 MISSING AUTHENTICATION FOR CRITICAL FUNCTION CWE-306 Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to trigger the WriteConfiguration method, which could allow an attacker to provide new values for user configuration files such as UserListInfo.xml. This could lead to the changing of administrative passwords. CVE-2022-41776 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is ( AV:N/AC:L/PR:N/UI:N/S:U/ C:N/I:H/A:N ). 4.2.10 MISSING AUTHENTICATION FOR CRITICAL FUNCTION CWE-306 Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to access the aprunning endpoint, which could allow an attacker to retrieve any file from the "RunningConfigs" directory. The attacker could then view and modify configuration files such as UserListInfo.xml, which would allow them to see existing administrative passwords. CVE-2022-41629 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is ( AV:N/AC:L/PR:N/UI:N/S:U/ C:H/I:N/A:N ). 4.3 BACKGROUND o CRITICAL INFRASTRUCTURE SECTORS: Energy o COUNTRIES/AREAS DEPLOYED: Worldwide o COMPANY HEADQUARTERS LOCATION: Taiwan 4.4 RESEARCHER kimiya, working with Trend Micro Zero Day Initiative, reported these vulnerabilities to CISA. 5. MITIGATIONS - --------- Begin Update A part 2 of 2 --------- Delta Electronics recommends users uninstall old versions of InfraSuite Device Master and reinstall the updated Version 1.0.3 using the installer . - --------- End Update A part 2 of 2 --------- Delta Electronics also recommends users follow CISA's security recommendations. CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability these vulnerabilities. Specifically, users should: o Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet . o Locate control system networks and remote devices behind firewalls and isolate them from business networks. o When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage at cisa.gov/ics . Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies . Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies . Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploits specifically target these vulnerabilities. For any questions related to this report, please contact the CISA at: Email: CISAservicedesk@cisa.dhs.gov Toll Free: 1-888-282-0870 CISA continuously strives to improve its products and services. You can help by choosing one of the links below to provide feedback about this product. - --------------------------END INCLUDED TEXT-------------------- You have received this e-mail bulletin as a result of your organisation's registration with AusCERT. The mailing list you are subscribed to is maintained within your organisation, so if you do not wish to continue receiving these bulletins you should contact your local IT manager. If you do not know who that is, please send an email to auscert@auscert.org.au and we will forward your request to the appropriate person. NOTE: Third Party Rights This security bulletin is provided as a service to AusCERT's members. As AusCERT did not write the document quoted above, AusCERT has had no control over its content. The decision to follow or act on information or advice contained in this security bulletin is the responsibility of each user or organisation, and should be considered in accordance with your organisation's site policies and procedures. AusCERT takes no responsibility for consequences which may arise from following or acting on information or advice contained in this security bulletin. NOTE: This is only the original release of the security bulletin. It may not be updated when updates to the original are made. If downloading at a later date, it is recommended that the bulletin is retrieved directly from the author's website to ensure that the information is still current. Contact information for the authors of the original document is included in the Security Bulletin above. If you have any questions or need further information, please contact them directly. Previous advisories and external security bulletins can be retrieved from: https://www.auscert.org.au/bulletins/ =========================================================================== Australian Computer Emergency Response Team The University of Queensland Brisbane Qld 4072 Internet Email: auscert@auscert.org.au Facsimile: (07) 3365 7031 Telephone: (07) 3365 4417 (International: +61 7 3365 4417) AusCERT personnel answer during Queensland business hours which are GMT+10:00 (AEST). On call after hours for member emergencies only. =========================================================================== -----BEGIN PGP SIGNATURE----- Comment: https://auscert.org.au/gpg-key/ iQIVAwUBY79TmskNZI30y1K9AQgSig//V9B6nlOwQkzDHduZWAK9+iOoUKAivDJO 6tdztNRSuEKj5+JVqI4/3IDsAsJ/+H/sbikpAhp/E0M4cmbcZsUKGdguwkBLFevd ZZaqkr95cHw//Rl4ZKPazxKSQONONmZKoiueD6A4M2hXZSC2ynDmdtSrcj1vHGh4 IaapQ05+rUlRWIuksiZFq2M3R6zOcR4P5lTwBgWz4/yCKYLdm3834Aj5vd4CIX7P iFftisEtZrG4zUXpnojMmeP92zC7qJQaluUvCImk6DH4RrnUgfb6mvBKQN90MdF2 FPKlXJG52rM8qXaNgrJrWFl9bsiWLe9s0teuyy0RistG0GfFDaZktH+K3d3ZjhdP RIwhgHB4wLXgD1AMGcjbMz5GWkcuynNq6lVm8pLFXIXjrmQABFkWpZB4Rk2hWHBp cI2xkWIrIJOFuFBtkjBeHoIEjLL1F3cXUmQ/If2QFgbwKJdyjUMDCJusdM2MCFoF mKmCeyb6weeGPKilZvhNvHcamP/gIq3bypBOwxXDcxGPZSWqY1FY6yDonnYYQexx NG1LZFs8g3kJ3EB85IIvqf8rhWrVYscZ64ZFaWoRCAVSKvxHLrt74yZPjCnuHDmb X0AzpVprp4nBW9tW0fRhV6uxnGUdPtxdQGjzTNwuHYdox9m8ptTq1KGI1bRwz2YY sycjSATHvaM= =Kb6D -----END PGP SIGNATURE-----