Protect yourself against future threats.
-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA256 =========================================================================== AUSCERT External Security Bulletin Redistribution ESB-2022.4071 ICS Advisory (icsa-22-228-01) Yokogawa CENTUM Controller FCS 17 August 2022 =========================================================================== AusCERT Security Bulletin Summary --------------------------------- Product: Yokogawa CENTUM Controller FCS Publisher: ICS-CERT Operating System: Network Appliance Resolution: Patch/Upgrade CVE Names: CVE-2022-33939 Original Bulletin: https://us-cert.cisa.gov/ics/advisories/icsa-22-228-01 Comment: CVSS (Max): 6.5 CVE-2022-33939 (CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H) CVSS Source: ICS-CERT Calculator: https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H - --------------------------BEGIN INCLUDED TEXT-------------------- ICS Advisory (ICSA-22-228-01) Yokogawa CENTUM Controller FCS Original release date: August 16, 2022 Legal Notice All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/ . 1. EXECUTIVE SUMMARY o CVSS v3 6.5 o ATTENTION: Exploitable remotely/low attack complexity o Vendor: Yokogawa o Equipment: CENTUM VP & CS 3000 Controller FCS o Vulnerability: Denial of Service 2. RISK EVALUATION Successful exploitation of this vulnerability could crash the affected device, resulting in a denial-of-service condition. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Yokogawa reports this vulnerability affects the following CENTUM VP/CS 3000 Controller FCS products: o CENTUM VP/CS 3000 controller FCS o CP31, CP33, CP345 o CP401, CP451 3.2 VULNERABILITY OVERVIEW 3.2.1 RESOURCE MANAGEMENT ERRORS CWE-399 The Yokogawa CENTUM VP/CS 3000 Controller FCS is vulnerable to a denial-of-service attack caused by a malformed packet. This attack may stop inter-station data link block (ADL) communications. CVE-2022-33939 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been assigned; the CVSS vector string is ( AV:A/AC:L/PR:N/UI:N/S:U/C:N/ I:N/A:H ). 3.3 BACKGROUND o CRITICAL INFRASTRUCTURE SECTORS: Multiple Sectors o COUNTRIES/AREAS DEPLOYED: Worldwide o COMPANY HEADQUARTERS LOCATION: Japan 3.4 RESEARCHER Noriko Takahashi of JPCERT/CC reported this vulnerability to CISA. 4. MITIGATIONS Yokogawa has listed the following products as vulnerable due to end-of-life status, with no software patch available: o CENTUM CS 3000 o CENTUM CS 3000 Entry Class o CENTUM VP (R4.01.00 to R4.03.00) o CENTUM VP Entry Class (R4.01.00 to R4.03.00) Yokogawa has provided software patches for the following vulnerable products: o CENTUM VP (R5.01.00 to R5.04.20) o CENTUM VP Entry Class (R6.01.00 to R6.03.00) For more information and details on implementing these mitigations and downloading the latest patch, users should see the Yokogawa advisory . CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should: o Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet . o Locate control system networks and remote devices behind firewalls and isolate them from business networks. o When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage at cisa.gov/ics . Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies . Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies . Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploits specifically target this vulnerability. For any questions related to this report, please contact the CISA at: Email: CISAservicedesk@cisa.dhs.gov Toll Free: 1-888-282-0870 CISA continuously strives to improve its products and services. You can help by choosing one of the links below to provide feedback about this product. - --------------------------END INCLUDED TEXT-------------------- You have received this e-mail bulletin as a result of your organisation's registration with AusCERT. The mailing list you are subscribed to is maintained within your organisation, so if you do not wish to continue receiving these bulletins you should contact your local IT manager. If you do not know who that is, please send an email to auscert@auscert.org.au and we will forward your request to the appropriate person. NOTE: Third Party Rights This security bulletin is provided as a service to AusCERT's members. As AusCERT did not write the document quoted above, AusCERT has had no control over its content. The decision to follow or act on information or advice contained in this security bulletin is the responsibility of each user or organisation, and should be considered in accordance with your organisation's site policies and procedures. AusCERT takes no responsibility for consequences which may arise from following or acting on information or advice contained in this security bulletin. NOTE: This is only the original release of the security bulletin. It may not be updated when updates to the original are made. If downloading at a later date, it is recommended that the bulletin is retrieved directly from the author's website to ensure that the information is still current. Contact information for the authors of the original document is included in the Security Bulletin above. If you have any questions or need further information, please contact them directly. Previous advisories and external security bulletins can be retrieved from: https://www.auscert.org.au/bulletins/ =========================================================================== Australian Computer Emergency Response Team The University of Queensland Brisbane Qld 4072 Internet Email: auscert@auscert.org.au Facsimile: (07) 3365 7031 Telephone: (07) 3365 4417 (International: +61 7 3365 4417) AusCERT personnel answer during Queensland business hours which are GMT+10:00 (AEST). On call after hours for member emergencies only. =========================================================================== -----BEGIN PGP SIGNATURE----- Comment: https://auscert.org.au/gpg-key/ iQIVAwUBYvxMXckNZI30y1K9AQjvRw/+LZ6cpFnEQcbpUOVHdgtpSwnBEO0mACwS WS0DNHA47DcVb/iIc+ywNtsKghkIb0UtwMO5KajC7MQ3lt2BQt6QLJzMm+O+gxlY s0EJaXWZyxC+5kSlkVm4pSAarh9pcCTKvBHJt3C6n67gRPxkeyec27YGlnvYVfju cfkHNNkGMQ3X6XnbEM7bI6yWRidUwIRV9SQT/2sZqmreLomzC5gRf/lb7yg59Uvd f+lm3EWhB6ArEOih97iaqnflFwUmXchZ8YcaLsCIeVfYbR4d8ccACPowHj03cdbc 4WL57hnmEG9g1QOnF9vrH7dhPHjvUa/GvGOx49e6aqpLNHy0a5uXf7EzZ1t+e2wS QjIo2+8D5sY+hCyrpBtfFHvOKPLQuY5zyRh/EvI8ibBOfQEYoNSh5gbU0hBVjMSi Lvd9knQpoPItRSpAz/UIXqpVB9qgLcBu/QXc975/ar6BEvOz0iZJWvivqjczEfXm sD889ZdviJ1dPDMJx2q9tFOgAMYziG6hN6npTj4tJu9/AJaZIJbE3POf3Yxq+ekp g2BmNMI4B0oxdhO1AmLfg+a6twMiZQ22hlUtAsVqm5z0LoBheGAHFnlvUAwPZ6FQ pLcILKr43ZdkiNoUSex+k4DNpo5gzgBRDSUzvXhoc2UEAmrdpBv6xmW1z6BMWpl+ I/fQRNdun1Y= =KTn6 -----END PGP SIGNATURE-----