Protect yourself against future threats.
-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA256 =========================================================================== AUSCERT External Security Bulletin Redistribution ESB-2022.3140.2 Advisory (icsa-22-179-02) Omron SYSMAC CS/CJ/CP Series and NJ/NX Series 10 February 2023 =========================================================================== AusCERT Security Bulletin Summary --------------------------------- Product: Omron SYSMAC CS/CJ/CP Series and NJ/NX Series Publisher: ICS-CERT Operating System: Network Appliance Resolution: Patch/Upgrade CVE Names: CVE-2022-31207 CVE-2022-31206 CVE-2022-31205 CVE-2022-31204 Original Bulletin: https://us-cert.cisa.gov/ics/advisories/icsa-22-179-02 Revision History: February 10 2023: Vendor updated advisory June 29 2022: Initial Release - --------------------------BEGIN INCLUDED TEXT-------------------- ICS Advisory (ICSA-22-179-02) Omron SYSMAC CS/CJ/CP Series and NJ/NX Series (Update A) Original release date: February 09, 2023 Legal Notice All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/ . 1. EXECUTIVE SUMMARY o CVSS v3 6.5 o ATTENTION: Exploitable remotely/low attack complexity o Vendor: Omron o Equipment: SYSMAC CS/CJ/CP Series and NJ/NX Series o Vulnerabilities: Cleartext Transmission of Sensitive Information, Insufficient Verification of Data Authenticity, Plaintext Storage of a Password CISA is aware of a public report, known as "OT:ICEFALL" that details vulnerabilities found in multiple operational technology (OT) vendors. CISA is issuing this advisory to provide notice of the reported vulnerabilities and identify baseline mitigations for reducing risks to these and other cybersecurity attacks. 2. UPDATE OR REPOSTED INFORMATION This updated advisory is a follow-up to the original advisory titled ICSA-22-179-02 Omron SYSMAC CS-CJ-CP Sieries and NJ-NX Sieries that was published June 28, 2022, on the ICS webpage on cisa.gov/ICS. 3. RISK EVALUATION Successful exploitation of these vulnerabilities could cause a denial-of-service condition and allow remote code execution. 4. TECHNICAL DETAILS 4.1 AFFECTED PRODUCTS The following versions of the Omron SYSMAC CS/CJ/CP Series and NJ/NX Series, a programmable logic controller, are affected: - --------- Begin Update A part 1 of 4 --------- o SYSMAC CS1H/CJ1G: Versions prior to 4.1 o SYSMAC CS1D-CPU[][]H/P/HA: Versions prior to 1.4 o SYSMAC CS1D-CPU[][]S/SA: Versions prior to 2.1 - --------- End Update A part 1 of 4 --------- o SYSMAC CJ2M: Versions prior to 2.1 o SYSMAC CJ2H: Versions prior to 1.5 o SYSMAC CP1E/CP1H: Versions prior to 1.30 - --------- Begin Update A part 2 of 4 --------- o SYSMAC CP1L: Versions prior to 1.1 - --------- End Update A part 2 of 4 --------- o CP1W-CIF41: All versions o SYSMAC CX-Programmer: Versions prior to 9.6 o SYSMAC NJ/NX Series: Versions prior to 1.49 (1.29 for NX7) 4.2 VULNERABILITY OVERVIEW 4.2.1 CLEARTEXT TRANSMISSION OF SENSITIVE INFORMATION CWE-319 Omron SYSMAC CS1/CJ1/CP1/CP2 series is vulnerable to a password used to restrict engineering operation is transmitted in plaintext. CVE-2022-31204 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been assigned; the CVSS vector string is ( AV:N/AC:L/PR:N/UI:R/S:U/C:H/ I:N/A:N ). 4.2.2 PLAINTEXT STORAGE OF A PASSWORD CWE-256 The CP1W-CIF41 Ethernet Option Board is vulnerable to a Web UI password that can be read from memory using the Omron FINS protocol. An attacker obtaining this password could change the network settings of the option board. CVE-2022-31205 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been assigned; the CVSS vector string is ( AV:N/AC:L/PR:N/UI:R/S:U/C:H/ I:N/A:N ). 4.2.3 INSUFFICIENT VERIFICATION OF DATA AUTHENTICITY CWE-345 The logic that is downloaded to the PLC is not cryptographically authenticated, allowing an attacker to manipulate transmitted object code to an unprotected PLC without using the PLC protection password. An attacker could then execute arbitrary object code commands on the defined software logic for all versions of SYSMAC CS/CJ/CP series controllers and cause a denial-of-service condition. CVE-2022-31207 has been assigned to this vulnerability. A CVSS v3 base score of 5.9 has been assigned; the CVSS vector string is ( AV:N/AC:H/PR:H/UI:N/S:U/C:N/ I:H/A:H ). 4.2.4 INSUFFICIENT VERIFICATION OF DATA AUTHENTICITY CWE-347 The logic that is downloaded to the PLC is not cryptographically authenticated, allowing an attacker to manipulate transmitted object code to the PLC and execute arbitrary machine code on the processor of the PLC's CPU module for SYSMAC NJ/NX series controllers. CVE-2022-31206 has been assigned to this vulnerability. A CVSS v3 base score of 4.4 has been assigned; the CVSS vector string is ( AV:N/AC:H/PR:H/UI:N/S:U/C:N/ I:H/A:N ). 4.3 BACKGROUND o CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing o COUNTRIES/AREAS DEPLOYED: Worldwide o COMPANY HEADQUARTERS LOCATION: Japan 4.4 RESEARCHER Daniel dos Santos and Jos Wetzels from Forescout Technologies reported these vulnerabilities to CISA. 5. MITIGATIONS For CVE-2022-31204: Omron recommends users implement an extended password protection function in the following product versions: - --------- Begin Update A part 3 of 4 --------- o SYSMAC CS1H/CJ1G: v4.1 or later o SYSMAC CS1D-CPU[][]H/P/HA: v1.4 or later o SYSMAC CS1D-CPU[][]S/SA: v2.1 or later - --------- End Update A part 3 of 4 --------- o CJ2M, v2.1 or later o CJ2H, v1.5 or later o CP1E/CP1H , v1.30 or later - --------- Begin Update A part 4 of 4 --------- o CP1L, v1.1 or later - --------- End Update A part 4 of 4 --------- o CX-Programmer, v9.6 or higher For CVE-2022-31206: Omron intends to publish an update for SYSMAC NJ/NX in July 2022. For CVE-2022-31207: Omron recommends users of SYSMAC CS/CJ/CP Series to use the PLC protection password and enable protection against unauthorized write access to address. Also, there are hardware DIP switches on the PLC which can prevent unauthorized PLC program changes regardless of password. For CVE-2022-31205: Omron recommends using different passwords between the CP1W-CIF41 Ethernet Option Board and CP1 PLC itself. The Web UI password will not grant access to the PLC. CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should: o Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet . o Locate control system networks and remote devices behind firewalls and isolate them from the business network. o When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage at cisa.gov/ics . Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies . Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies . Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents. No known public exploits specifically target these vulnerabilities. For any questions related to this report, please contact the CISA at: Email: CISAservicedesk@cisa.dhs.gov Toll Free: 1-888-282-0870 CISA continuously strives to improve its products and services. You can help by choosing one of the links below to provide feedback about this product. - --------------------------END INCLUDED TEXT-------------------- You have received this e-mail bulletin as a result of your organisation's registration with AusCERT. The mailing list you are subscribed to is maintained within your organisation, so if you do not wish to continue receiving these bulletins you should contact your local IT manager. If you do not know who that is, please send an email to auscert@auscert.org.au and we will forward your request to the appropriate person. NOTE: Third Party Rights This security bulletin is provided as a service to AusCERT's members. As AusCERT did not write the document quoted above, AusCERT has had no control over its content. The decision to follow or act on information or advice contained in this security bulletin is the responsibility of each user or organisation, and should be considered in accordance with your organisation's site policies and procedures. AusCERT takes no responsibility for consequences which may arise from following or acting on information or advice contained in this security bulletin. NOTE: This is only the original release of the security bulletin. It may not be updated when updates to the original are made. If downloading at a later date, it is recommended that the bulletin is retrieved directly from the author's website to ensure that the information is still current. Contact information for the authors of the original document is included in the Security Bulletin above. If you have any questions or need further information, please contact them directly. Previous advisories and external security bulletins can be retrieved from: https://www.auscert.org.au/bulletins/ =========================================================================== Australian Computer Emergency Response Team The University of Queensland Brisbane Qld 4072 Internet Email: auscert@auscert.org.au Facsimile: (07) 3365 7031 Telephone: (07) 3365 4417 (International: +61 7 3365 4417) AusCERT personnel answer during Queensland business hours which are GMT+10:00 (AEST). On call after hours for member emergencies only. =========================================================================== -----BEGIN PGP SIGNATURE----- Comment: https://auscert.org.au/gpg-key/ iQIVAwUBY+XE4ckNZI30y1K9AQgbgBAAsr9tLHSEWpflXg5k9y4I/FrnACmf/BYV wFKak1ErWd4scxSaSpZRyrUM0nFCnAqLsG/88L554jtdUJDMYzcmSz378fPyKNq7 eK08qOPdziPUF9EYtIU1ATexqgLby0nhGPg/b8rpRXZAUK8UrUzfKjLvMbGw2r9V 3sJVvh5DujFwoOR+OfPKoTEmYHIOiz1jDZh5Go6XQCUY2F4iTZCFs/TA7IP+ywTC hDFgmawcOkqY93OsI3Pq2BCW2Qs8/tMxlYRnChTXt/tVAvQ+OfZA0FI/dkMH9Mnz Gfso3ZaDE3OR9CslyMRMzR0ovstkgwhIK/6kXLlQGfcKFgkqm/RCGZ25BAVFbe8q YCPG/76wtiFInlmyDwzxjINtjU0KtA7Wuf8P0ZRy1h8lgXd5zumejpUUgREwFkVA U8wi8d0WibZP0qTB2i0WWIXmHh00hSlOyyBSrFy9pOCP48Xop+eN5L2NVoxlZrsL nEvdLT5VcTNbNJr4oK9VQVKrm+IH71Y4dGbbf6IJGre7Xnppc+sIRCY0kyWaShmr xCNiROBStFGuxUnLdOLfNlvuVPGni8aQUmf0cAZARjRkykd+6aDvK/Bn4aLU5313 5vwyn/3Be9B8CEw5ofRGF4n1kDnImTiNPiDREViStzC68PZXGf5f60DF+JnS9jZ9 6X7HbEHKZ2k= =jbM7 -----END PGP SIGNATURE-----