Protect yourself against future threats.
-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA256 =========================================================================== AUSCERT External Security Bulletin Redistribution ESB-2022.1120 Advisory (icsa-22-074-01) ABB OPC Server for AC 800M 16 March 2022 =========================================================================== AusCERT Security Bulletin Summary --------------------------------- Product: ABB OPC Server for AC 800M Publisher: ICS-CERT Operating System: Network Appliance Resolution: Patch/Upgrade CVE Names: CVE-2021-22284 Original Bulletin: https://us-cert.cisa.gov/ics/advisories/icsa-22-074-01 Comment: CVSS (Max): 8.4 CVE-2021-22284 (CVSS:3.0/AV:A/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H) CVSS Source: ICS-CERT Calculator: https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:A/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H - --------------------------BEGIN INCLUDED TEXT-------------------- ICS Advisory (ICSA-22-074-01) ABB OPC Server for AC 800M Original release date: March 15, 2022 Legal Notice All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/ . 1. EXECUTIVE SUMMARY o CVSS v3 8.4 o ATTENTION: Exploitable remotely/low attack complexity o Vendor: ASEA Brown Boveri (ABB) o Equipment: OPC Server for AC 800M o Vulnerability: Execution with Unnecessary Privileges 2. RISK EVALUATION Successful exploitation of this vulnerability could allow a low privileged authenticated user to remotely execute arbitrary code. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of OPC Server, a run-time data reader, are affected: 800xA, Control Software for AC 800M: o OPC Server for AC 800M: Versions 5.1.0-x, 5.1.1-x, 6.0.0-1 to 6.0.0-3 Control Builder Safe, 1.x and 2.0 including: o OPC Server for AC 800M: Versions 5.1.1-1 and 6.0.0-1 Compact Product Suite - Control and I/O: o OPC Server for AC 800M: Versions 5.1.0-x, 5.1.1-x, 6.0.0-x 3.2 VULNERABILITY OVERVIEW 3.1.1 EXECUTION WITH UNNECESSARY PRIVILEGES CWE-250 The affected products are vulnerable to an authenticated remote user with low privileges who could successfully insert and execute arbitrary code in the node running the AC 800M OPC Server. CVE-2021-22284 has been assigned to this vulnerability. A CVSS v3 base score of 8.4 has been assigned; the CVSS vector string is ( AV:A/AC:L/PR:L/UI:R/S:C/C:H/ I:H/A:H ). 3.3 BACKGROUND o CRITICAL INFRASTRUCTURE SECTORS: Multiple o COUNTRIES/AREAS DEPLOYED: Worldwide o COMPANY HEADQUARTERS LOCATION: Switzerland 3.4 RESEARCHER William Knowles of Applied Risk reported this vulnerability to CISA. 4. MITIGATIONS ABB advises affected users to install the updates to address the vulnerability as follows: o 800xA control software for AC 800M to v6.1.0-0 or later. o 800xA, Control Software for AC 800M update to 6.0.0-4 (scheduled for release later in 2022). Contact ABB for update information. Users unable to install the update are advised to review the Mitigations and Workarounds section of the ABB advisory for additional advice on how to reduce the risk associated with this vulnerability. CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should: o Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet . o Locate control system networks and remote devices behind firewalls and isolate them from the business network. o When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov . Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies . Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies . Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents. No known public exploits specifically target this vulnerability. For any questions related to this report, please contact the CISA at: Email: CISAservicedesk@cisa.dhs.gov Toll Free: 1-888-282-0870 CISA continuously strives to improve its products and services. You can help by choosing one of the links below to provide feedback about this product. - --------------------------END INCLUDED TEXT-------------------- You have received this e-mail bulletin as a result of your organisation's registration with AusCERT. The mailing list you are subscribed to is maintained within your organisation, so if you do not wish to continue receiving these bulletins you should contact your local IT manager. If you do not know who that is, please send an email to auscert@auscert.org.au and we will forward your request to the appropriate person. NOTE: Third Party Rights This security bulletin is provided as a service to AusCERT's members. As AusCERT did not write the document quoted above, AusCERT has had no control over its content. The decision to follow or act on information or advice contained in this security bulletin is the responsibility of each user or organisation, and should be considered in accordance with your organisation's site policies and procedures. AusCERT takes no responsibility for consequences which may arise from following or acting on information or advice contained in this security bulletin. NOTE: This is only the original release of the security bulletin. It may not be updated when updates to the original are made. If downloading at a later date, it is recommended that the bulletin is retrieved directly from the author's website to ensure that the information is still current. Contact information for the authors of the original document is included in the Security Bulletin above. If you have any questions or need further information, please contact them directly. Previous advisories and external security bulletins can be retrieved from: https://www.auscert.org.au/bulletins/ =========================================================================== Australian Computer Emergency Response Team The University of Queensland Brisbane Qld 4072 Internet Email: auscert@auscert.org.au Facsimile: (07) 3365 7031 Telephone: (07) 3365 4417 (International: +61 7 3365 4417) AusCERT personnel answer during Queensland business hours which are GMT+10:00 (AEST). On call after hours for member emergencies only. =========================================================================== -----BEGIN PGP SIGNATURE----- Comment: http://www.auscert.org.au/render.html?it=1967 iQIVAwUBYjEnGuNLKJtyKPYoAQgrIw//Tq06/be1M7AWrtQNoktz3CL2AQdlChSM ezj8RKYCbRa625ECgvP27cWRbExNRbXc3/6SjqXpftZ4tRLGs4wbM29HHD0dOSuz rtW8QuBUcLLj3sOSo1ZBnMHJ4FRU9wYJH4P0CZ/i3/WXj2Pi/Z5jrFyKCfWKGQmP xfNSJtGC3tgCUTqnNiINeiJdXiswu/MYv96Tl265HbL+7InvaS6WtKFB9V9eefdE pcOCwWxYgeoorfkvijku5Uce+F/npyKk4XRJBBt4/AB+VO+xi1nld5hzQaT8yqQF bUXeVSBtLnf6SvcE958ErbF24t+1D8rT1xBmGO95nyzXMuK60IZS8MaZDCYfrsKU Uy4np0CiLY+DIHQRmn4FvtztnFMJDhbzxgckh80bKwwAU/OTKqV4ELBT1/KKZZsZ ZnuPc1mmkTxkm5SZ+2JkNA4tAFifVI7BUTFYHvW2/pxki9kDUM2OfTz/SXOpffIj 2GF9PhmaUV8YWHdPaMm9S61PQI8lcpO7doqxILkEYOj1bo2RR9L0hl+ZpOOoysjW 6iwZpbkTO1DNPvFm0/uY0eAEDPJVfhyLb8XiDGF3rfFIUp+qYZ+WYw+BetL3Iww8 hETXfTPDnUlY7CzD4Cok4QaL1GKFtFWud5cHFigaHa8KrroRiRWUrpI6rtHCK8BC VmPaWD0lgBI= =ew01 -----END PGP SIGNATURE-----