-----BEGIN PGP SIGNED MESSAGE-----
Hash: SHA256

===========================================================================
             AUSCERT External Security Bulletin Redistribution

                               ESB-2021.4149
                      Hitachi Energy XMC20 and FOX61x
                              8 December 2021

===========================================================================

        AusCERT Security Bulletin Summary
        ---------------------------------

Product:           Hitachi Energy XMC20
                   Hitachi Energy FOX61x
Publisher:         ICS-CERT
Operating System:  Network Appliance
Impact/Access:     Denial of Service        -- Remote/Unauthenticated
                   Access Confidential Data -- Existing Account      
                   Unauthorised Access      -- Existing Account      
Resolution:        Patch/Upgrade
CVE Names:         CVE-2021-40334 CVE-2021-40333 

Original Bulletin: 
   https://us-cert.cisa.gov/ics/advisories/icsa-21-341-02

- --------------------------BEGIN INCLUDED TEXT--------------------

ICS Advisory (ICSA-21-341-02)

Hitachi Energy XMC20 and FOX61x

Original release date: December 07, 2021

Legal Notice

All information products included in https://us-cert.cisa.gov/ics are provided
"as is" for informational purposes only. The Department of Homeland Security
(DHS) does not provide any warranties of any kind regarding any information
contained within. DHS does not endorse any commercial product or service,
referenced in this product or otherwise. Further dissemination of this product
is governed by the Traffic Light Protocol (TLP) marking in the header. For more
information about TLP, see https://us-cert.cisa.gov/tlp/ .



1. EXECUTIVE SUMMARY

  o CVSS v3 9.0
  o ATTENTION: Exploitable remotely/low attack complexity
  o Vendor: Hitachi Energy
  o Equipment: XMC20 and FOX61x
  o Vulnerabilities: Weak Password Requirements, Missing Handler

2. RISK EVALUATION

Successful exploitation of these vulnerabilities could allow an attacker to
gain unauthorized access to the Data Communication Network (DCN) routing
configuration and cause a disruption to the Network Management (NMS) and
Network Element (NE) communication.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following versions of XMC20 and FOX61x, multi-service network elements, are
affected:

  o XMC20: All versions prior to R15A
  o FOX61x: All versions prior to R15A

3.2 VULNERABILITY OVERVIEW

3.2.1 WEAK PASSWORD REQUIREMENTS CWE-521

This vulnerability is a weak default credential associated with TCP Port 26.
Successful exploitation of this vulnerability could allow an attacker to gain
unauthorized access to the DCN routing configuration.

CVE-2021-40333 has been assigned to this vulnerability. A CVSS v3 base score of
9.0 has been calculated; the CVSS vector string is ( AV:N/AC:L/PR:H/UI:N/S:C/
C:L/I:H/A:H ).

3.2.2 MISSING HANDLER CWE-431

This vulnerability is due to the implementation of the proprietary management
protocol (TCP Port 5558), in which if SSH is activated, could cause a
disruption to the NMS and NE communication.

CVE-2021-40334 has been assigned to this vulnerability. A CVSS v3 base score of
8.6 has been calculated; the CVSS vector string is ( AV:N/AC:L/PR:N/UI:N/S:C/
C:N/I:N/A:H ).

3.3 BACKGROUND

  o CRITICAL INFRASTRUCTURE SECTORS: Multiple Sectors
  o COUNTRIES/AREAS DEPLOYED: Worldwide
  o COMPANY HEADQUARTERS LOCATION: Switzerland

3.4 RESEARCHER

Hitachi Energy reported these vulnerabilities to CISA.

4. MITIGATIONS

Hitachi Energy recommends users to upgrade to the most current version of their
products:

  o XMC20: Upgrade to Version R15A
  o FOX61x: Upgrade to Version R15A

Please refer to the Hitachi Energy XMC20 advisory for more details on affected
module information.

Please refer to the Hitachi Energy FOX61x advisory for more details on affected
module information.

Hitachi Energy recommends the following security practices and firewall
configurations to help protect process control networks from attacks that
originate from outside the network:

  o Physically protect process control systems from direct access by
    unauthorized personnel.
  o Do not directly connect to the Internet.
  o Separate from other networks by means of a firewall system that has a
    minimal number of ports exposed.
  o Portable computers and removable storage media should be carefully scanned
    for viruses before they are connected to a control system.

For additional information and access to updated firmware, please contact the
Hitachi Energy service organization .

CISA recommends users take defensive measures to minimize the risk of
exploitation of these vulnerabilities. Specifically, users should:

  o When remote access is required, use secure methods, such as virtual private
    networks (VPNs), recognizing VPNs may have vulnerabilities and should be
    updated to the most current version available. Also recognize VPN is only
    as secure as its connected devices.

CISA reminds organizations to perform proper impact analysis and risk
assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices
on the ICS webpage on us-cert.cisa.gov . Several recommended practices are
available for reading and download, including Improving Industrial Control
Systems Cybersecurity with Defense-in-Depth Strategies .

Additional mitigation guidance and recommended practices are publicly available
on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper,
ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation
Strategies .

Organizations observing any suspected malicious activity should follow their
established internal procedures and report their findings to CISA for tracking
and correlation against other incidents.

No known public exploits specifically target these vulnerabilities.

For any questions related to this report, please contact the CISA at:

Email: CISAservicedesk@cisa.dhs.gov
Toll Free: 1-888-282-0870

CISA continuously strives to improve its products and services. You can help by
choosing one of the links below to provide feedback about this product.

- --------------------------END INCLUDED TEXT--------------------

You have received this e-mail bulletin as a result of your organisation's
registration with AusCERT. The mailing list you are subscribed to is
maintained within your organisation, so if you do not wish to continue
receiving these bulletins you should contact your local IT manager. If
you do not know who that is, please send an email to auscert@auscert.org.au
and we will forward your request to the appropriate person.

NOTE: Third Party Rights
This security bulletin is provided as a service to AusCERT's members.  As
AusCERT did not write the document quoted above, AusCERT has had no control
over its content. The decision to follow or act on information or advice
contained in this security bulletin is the responsibility of each user or
organisation, and should be considered in accordance with your organisation's
site policies and procedures. AusCERT takes no responsibility for consequences
which may arise from following or acting on information or advice contained in
this security bulletin.

NOTE: This is only the original release of the security bulletin.  It may
not be updated when updates to the original are made.  If downloading at
a later date, it is recommended that the bulletin is retrieved directly
from the author's website to ensure that the information is still current.

Contact information for the authors of the original document is included
in the Security Bulletin above.  If you have any questions or need further
information, please contact them directly.

Previous advisories and external security bulletins can be retrieved from:

        https://www.auscert.org.au/bulletins/

===========================================================================
Australian Computer Emergency Response Team
The University of Queensland
Brisbane
Qld 4072

Internet Email: auscert@auscert.org.au
Facsimile:      (07) 3365 7031
Telephone:      (07) 3365 4417 (International: +61 7 3365 4417)
                AusCERT personnel answer during Queensland business hours
                which are GMT+10:00 (AEST).
                On call after hours for member emergencies only.
===========================================================================
-----BEGIN PGP SIGNATURE-----
Comment: http://www.auscert.org.au/render.html?it=1967

iQIVAwUBYa/yIeNLKJtyKPYoAQj7nRAAla3L5sCBOurQPeKLHdOiyc3FuSYOYF25
kBHfiEms0+KKzxxZvGlJ0kHt6g0rKS59KaI4dpduIkELU/uFJkhGi3ZttL7bxRAt
P4WlKAZ7V/qlYM1+cM8TpwE5mtCxJpWpC6gAVmtnY3fR3Hn6IRoGH+9mhq7sPham
7keoDvsm5+vF0BpBuwj7uz4zEhFQOQLJrjxUVI7nrH9lDFtFdNRPyCxHljyB6Bv5
u7E+Ey6VS5m5mQzAr5UAGoi8jer1nedfq6PLeSBKrnRiPPN4FsM+u4hkdURudC+Y
NAdGDQx6gUaMRsJO9wz96Ypowx7spCVsxbCz3/jHnP9NQ+1vo/uZy6nbAw7GIlvP
tSNCWM9ceSiHTr2Ep9u61zhCOTjeOvsloDrElugTOt3Q9528O+YxgdlPrVJ0iCiy
SsAQUnyM8LPbRfcPFeEp6a0YpaBzhfHd6ANd21C6Q+zTJBfRjQPl4z5UzHvmoTf1
97WmwpbwgVqXPFqlCWvln/Vd/GDnPSazrsYEHezgdVFLbfH0KFfDMiSWWckuHXYF
eQw8C83wxVPTqZskOSRMs2kj7gfFsbtc4GcPHsZZVdNhiG6TKwFK1iCRFiZRkGvH
GMLaR2YjTI6wO5SbYPTrDCaNz0Oj7N8OXj/FpsNoKQ+Mbn6rBBlJN2Qb4FXTBhQ0
3RZhk57kGwQ=
=HscU
-----END PGP SIGNATURE-----